Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle

Zhenwei Li, Qingqing Xu, Ning Huangfu, Zewei Sun, Jia Su

Clinical Cardiology · 2023

DOI: 10.1002/clc.23992 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Cardiology, 2023. Verfasst von Zhenwei Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Ningbo Hospital of Zhejiang University, Ningbo, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pacemaker, Artificial. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Technology R&D Program of Ningbo, The Key Laboratory of Precision Medicine for Atherosclerotic Diseases of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Left bundle branch pacemakers (LBBPs) can better maintain ventricular electrical synchronization than traditional right ventricular pacing (RVP). Temporary cardiac pacing (TCP) is needed to ensure the safety of the operation in patients undergoing LBBP. Currently, there are two methods of installing TCP in conventional permanent pacemaker implantation. Hypothesis : To evaluate the safety and efficiency of replacing femoral vein pacing with atrial spiral pacing in the right ventricle for temporary cardiac pacing (TCP) during left bundle branch pacemaker (LBBP) implantation.

Method

A total of 179 patients who underwent TCP during LBBP were selected for retrospective analysis from April 2019 to 2021 and divided into two groups: the atrial spiral electrode group ( n = 76) and the femoral vein electrode group ( n = 103). The following were observed: operation time; radiation dose; radiation time; operation expenses; hospitalization time; pacemaker parameters immediately after the operation and at 1 week, 1 month, 3 months, and 6 months after the operation; operation complications and femoral vein puncture point complications were observed in the two groups.

Results

Compared to the femoral vein electrode group, the atrial electrode group had significantly lower operation times ([116.86 ± 24.63] versus [128.94 ± 25.27] min, p < 0.05), radiation doses ([805.07 ± 132.94] versus [846.42 ± 87.37] mgy, p < 0.05), and decreased risk of a displaced or dislodged temporary pacing electrode during the operation ([0.00%] versus [4.85%], p < 0.05). The atrial electrode group did not have significant operation costs or material costs associated with femoral vein temporary pacing electrode implantation. In addition, the atrial electrode group did not have an increased risk of pacemaker‐related infections, and the parameters of the pacemaker were unaffected. However, some puncture point complications appeared in the femoral vein electrode group (8 cases of local subcutaneous hematoma, 3 cases of pseudoaneurysms, 3 cases of arteriovenous fistula).

Conclusion

The replacement of the femoral vein pacing electrode with an atrial spiral pacing electrode in the right ventricle for TCP during LBBP implantation was safe and effective.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPacemaker, ArtificialHumansHeart VentriclesCardiac Pacing, ArtificialRetrospective StudiesFemoral VeinElectrocardiographyTreatment Outcome

Stichwörter der Autor:innen

atrial spiral pacemaker electrodefemoral vein pacemaker electrodeleft bundle branch pacemaker

Autor:innen und Institutionen

  • Department of Cardiology, Ningbo Hospital of Zhejiang University, Ningbo, China.
  • Department of Nephrology, Ningbo Hospital of Zhejiang University, Ningbo, China.
  • Department of Cardiology, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.

Förderung

  • Key Technology R&D Program of Ningbo
  • The Key Laboratory of Precision Medicine for Atherosclerotic Diseases of Zhejiang Province

Zitieren

APA

Li, Z., Xu, Q., Huangfu, N., Sun, Z., & Su, J. (2023). Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle. Clinical Cardiology. https://doi.org/10.1002/clc.23992

Vancouver

Li Z, Xu Q, Huangfu N, Sun Z, Su J. Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle. Clinical Cardiology. 2023. doi:10.1002/clc.23992

BibTeX
@article{Li2023,
  author = {Li, Zhenwei and Xu, Qingqing and Huangfu, Ning and Sun, Zewei and Su, Jia},
  title = {Comparison of the safety and efficiency of temporary cardiac pacing methods during left bundle branch pacemaker implantation: Femoral vein pacing versus atrial spiral pacing with electrodes placed at the ventricle},
  journal = {Clinical Cardiology},
  year = {2023},
  doi = {10.1002/clc.23992}
}
Kostenlos starten →