Resynchronization effects and clinical outcomes during left bundle branch area pacing with and without conduction system capture
Clinical Cardiology · 2023
DOI: 10.1002/clc.23969 ↗At a glance
Journal article in Clinical Cardiology, 2023. Written by Weiwei Zhang and 9 co-authors. Institution: Department of Cardiology, Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China. Major MEDLINE topics: Cardiac Resynchronization Therapy, Heart Failure. Cited 25 times so far (Crossref); 17 references. The full text is freely available (open access, CC BY 4.0). Funded by: Clinical Research Plan of SHDC, Informatization Development Project of Shanghai Municipal Commission of Economy and Informatization, Shanghai Chest Hospital Project of Collaborative Innovation.
Abstract (original language)
Background
Left bundle branch area pacing (LBBAP) includes left bundle branch pacing (LBBP) and left ventricular (LV) septal myocardial pacing (LVSP). Hypothesis The study aimed to assess resynchronization effects and clinical outcomes by LBBAP in heart failure (HF) patients with cardiac resynchronization therapy (CRT) indications.
Methods
LBBAP was successfully performed in 29 consecutive patients and further classified as the LBBP‐group ( N = 15) and LVSP‐group ( N = 14) based on the LBBP criteria and novel LV conduction time measurement (LV CT, between LBBAP site and LV pacing (LVP) site). AV‐interval optimized LBBP or LVSP, or LVSP combined with LVP (LVSP‐LVP) was applied. LV electrical and mechanical synchrony and clinical outcomes were assessed.
Results
All 15 patients in the LBBP‐group received optimized LBBP while 14 patients in the LVSP‐group received either optimized LVSP (5) or LVSP‐LVP (9). The LV CT during LBBP was significantly faster than that during LVP ( p < .001), while LV CT during LVSP were similar to LVP ( p = .226). The stimulus to peak LV activation time (Stim‐LVAT, 71.2 ± 8.3 ms) and LV mechanical synchrony (TSI‐SD, 35.3 ± 9.5 ms) during LBBP were significantly shorter than those during LVSP (Stim‐LVAT 89.1 ± 19.5 ms, TSI‐SD 49.8 ± 14.4 ms, both p < .05). Following 17(IQR 8) months of follow‐up, the improvement of LVEF (26.0%(IQR 16.0)) in the LBBP‐group was significantly greater than that in the LVSP‐group (6.0%(IQR 20.8), p = .001).
Conclusions
LV activation in LBBP propagated significantly faster than that of LVSP. LBBP generated superior electrical and mechanical resynchronization and better LVEF improvement over LVSP in HF patients with CRT indications.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
- Department of Ultrasound, Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
- Cardiac Rhythm and Heart Failure Division, Medtronic plc, Mounds View, Minnesota, USA.
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Funding
- Clinical Research Plan of SHDC
- Informatization Development Project of Shanghai Municipal Commission of Economy and Informatization
- Shanghai Chest Hospital Project of Collaborative Innovation
- Science and Technology Commission of Shanghai Municipality
Cite
APA
Zhang, W., Chen, L., Zhou, X., Huang, J., Zhu, S., Shen, E., Pan, C., Hou, X., Li, R., & He, B. (2023). Resynchronization effects and clinical outcomes during left bundle branch area pacing with and without conduction system capture. Clinical Cardiology. https://doi.org/10.1002/clc.23969
Vancouver
Zhang W, Chen L, Zhou X, Huang J, Zhu S, Shen E, et al. Resynchronization effects and clinical outcomes during left bundle branch area pacing with and without conduction system capture. Clinical Cardiology. 2023. doi:10.1002/clc.23969
BibTeX
@article{Zhang2023,
author = {Zhang, Weiwei and Chen, Lu and Zhou, Xiaohong and Huang, Jingjuan and Zhu, Shiwei and Shen, E and Pan, Changqing and Hou, Xumin and Li, Ruogu and He, Ben},
title = {Resynchronization effects and clinical outcomes during left bundle branch area pacing with and without conduction system capture},
journal = {Clinical Cardiology},
year = {2023},
doi = {10.1002/clc.23969}
}
EUVIMED