EUVIMEDEUVIMED entdecken
Crossref

Non‐Enzymatic Detection of Cardiac Troponin‐I with Graphene Oxide Quenched Fluorescent Iron Nanoclusters (FeNCs)

Ali Ibrahim Shkhair, Anju S Madanan, Susan Varghese, Merin K Abraham, Geneva Indongo, Greeshma Rajeevan, B K Arathy, Sara Muneer Abbas, Sony George iD

Chemistry – A European Journal · 04.11.2024 · 30 (61)

DOI: 10.1002/chem.202401867 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemistry – A European Journal, online erschienen am 16.10.2024. Verfasst von Ali Ibrahim Shkhair und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram, Kerala, 695581, …. Hauptthemen laut MEDLINE: Graphite, Troponin I, Fluorescence Resonance Energy Transfer, Fluorescent Dyes. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Indian Council for Cultural Relations.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac troponin I (cTnI) is the most resorted biomarker for the detection of cardiovascular disease (CVD). The means of rapid quantification of cTnI levels in the blood can substantially minimize the risk of acute myocardial infarction and heart failure. A sensor for the non‐enzymatic evaluation of cardiac troponin‐I has been developed using fluorescent iron nanoclusters via a one‐pot synthesis employing (BSA) as the template and reducing agent, and hydrogen peroxide as the additive. The fluorescence of Iron Nanocluster is quenched with graphene oxide (GO) via fluorescence resonance energy transfer (FRET) between conjugate iron nanoclusters and graphene oxide. The sensor shows a low detection limit of 0.011 ng/mL. The benefits of utilizing a non‐enzymatic probe for detecting cardiac troponin I is that it avoids the need for enzymes and hence is economical, stable, and less impacted by environmental conditions such as temperature and pH. Non‐enzymatic probes are more useful for clinical use since they are more stable and have a longer shelf life. The developed non‐enzymatic probes are also highly selective and sensitive to the target analyte, making them suitable for the direct detection of cardiac troponin I in actual biological samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteTroponin IFluorescence Resonance Energy TransferFluorescent DyesLimit of DetectionIronHumansHydrogen PeroxideBiomarkersBiosensing Techniques

Stichwörter der Autor:innen

Acute myocardial infarction (AMI)Cardiac biomarkerGraphene oxideIron nanoclusters (BSA@FeNCs)Non-enzymatic probe

Substanzen

GraphiteTroponin Igraphene oxideFluorescent DyesIronHydrogen PeroxideBiomarkers

Autor:innen und Institutionen

  • Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom Campus, Thiruvananthapuram, Kerala, 695581, India.
  • College of Food Science, Al-Qasim Green University, Babylon, 51013, Iraq.
  • Department of Chemistry, School of Physical and Mathematical Sciences, University of Kerala, Kariavattom campus, Thiruvananthapuram, Kerala, 695581, India Mob: +91-9446462933.

ORCID-Profile: Sony George

Förderung

  • Indian Council for Cultural Relations

Zitieren

APA

Ibrahim Shkhair, A., Madanan, A. S., Varghese, S., Abraham, M. K., Indongo, G., Rajeevan, G., Arathy, B. K., Muneer Abbas, S., & George, S. (2024). Non‐Enzymatic Detection of Cardiac Troponin‐I with Graphene Oxide Quenched Fluorescent Iron Nanoclusters (FeNCs). Chemistry – A European Journal, 30(61). https://doi.org/10.1002/chem.202401867

Vancouver

Ibrahim Shkhair A, Madanan AS, Varghese S, Abraham MK, Indongo G, Rajeevan G, et al. Non‐Enzymatic Detection of Cardiac Troponin‐I with Graphene Oxide Quenched Fluorescent Iron Nanoclusters (FeNCs). Chemistry – A European Journal. 2024;30(61). doi:10.1002/chem.202401867

BibTeX
@article{IbrahimShkhair2024,
  author = {Ibrahim Shkhair, Ali and Madanan, Anju S and Varghese, Susan and Abraham, Merin K and Indongo, Geneva and Rajeevan, Greeshma and Arathy, B K and Muneer Abbas, Sara and George, Sony},
  title = {Non‐Enzymatic Detection of Cardiac Troponin‐I with Graphene Oxide Quenched Fluorescent Iron Nanoclusters (FeNCs)},
  journal = {Chemistry – A European Journal},
  year = {2024},
  volume = {30},
  number = {61},
  doi = {10.1002/chem.202401867}
}
Kostenlos starten →