EUVIMEDEUVIMED entdecken
Fallbericht

Longitudinal Deployment Balloon Rupture With Uncomplicated Retrieval During TAVR

Ryotaro Iwata iD, Daisuke Fukamachi iD, Naoya Matsumoto iD, Yasuo Okumura iD

Catheterization and Cardiovascular Interventions · 11.11.2026

DOI: 10.1002/ccd.71020 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 11.11.2026. Verfasst von Ryotaro Iwata und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, Nihon University Hospital, Tokyo, Japan. Die Arbeit nennt 7 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Deployment‐balloon rupture during balloon‐expandable transcatheter aortic valve replacement can impede device retrieval. An octogenarian woman underwent transfemoral implantation of a 23‐mm SAPIEN 3 Ultra RESILIA valve. The balloon ruptured at approximately the nominal inflation volume adjacent to focal sinotubular‐junction calcification. Immediate aspiration produced complete collapse without residual contrast or abnormal balloon geometry, permitting resistance‐free retrieval into the 14‐F eSheath. Inspection demonstrated a longitudinal tear involving nearly the entire balloon length without circumferential separation or missing fragments. Tear orientation was identifiable only after retrieval; during the procedure, residual contrast, balloon geometry, response to aspiration, and withdrawal resistance guided management. This case suggests that rupture configuration may influence balloon collapse and retrievability, although the proposed relationship remains hypothesis‐generating.

Schlagwörter

Stichwörter der Autor:innen

SAPIEN 3 Ultra RESILIATAVRballoon rupturedevice retrievalsinotubular junction

Autor:innen und Institutionen

  • Division of Cardiology, Department of Medicine, Nihon University Hospital, Tokyo, Japan.
  • Division of Cardiology, Department of Medicine, Nihon University School of Medicine, Tokyo, Japan.

ORCID-Profile: Ryotaro Iwata, Daisuke Fukamachi, Naoya Matsumoto, Yasuo Okumura

Zitieren

APA

Iwata, R., Fukamachi, D., Matsumoto, N., & Okumura, Y. (2026). Longitudinal Deployment Balloon Rupture With Uncomplicated Retrieval During TAVR. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.71020

Vancouver

Iwata R, Fukamachi D, Matsumoto N, Okumura Y. Longitudinal Deployment Balloon Rupture With Uncomplicated Retrieval During TAVR. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.71020

BibTeX
@article{Iwata2026,
  author = {Iwata, Ryotaro and Fukamachi, Daisuke and Matsumoto, Naoya and Okumura, Yasuo},
  title = {Longitudinal Deployment Balloon Rupture With Uncomplicated Retrieval During TAVR},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.71020}
}
Kostenlos starten →