EUVIMEDOpdag EUVIMED
ÜbersichtsarbeitOpen access · CC BY-NC 4.0

Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring

Mizuki Miura iD, Yusuke Watanabe iD, Jo Omiya, Ken Kozuma iD

Catheterization and Cardiovascular Interventions · 2026-11-13

DOI: 10.1002/ccd.71010 ↗

At a glance

Übersichtsarbeit in Catheterization and Cardiovascular Interventions, published online on 2026-11-13. Written by Mizuki Miura and 3 co-authors. Institution: Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan. 3 references. The full text is freely available (open access, CC BY-NC 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

An 89‐year‐old man with structural deterioration of a surgical aortic bioprosthesis and renal dysfunction underwent zero‐contrast transcatheter aortic valve‐in‐surgical valve (TAV‐in‐SAV) implantation. A SavvyWire provided continuous left ventricular pressure monitoring and rapid pacing during the procedure. After implantation of a 23‐mm self‐expanding valve, a residual transvalvular gradient was detected, prompting balloon postdilatation under rapid pacing. Repeat invasive hemodynamic assessment showed improvement, and echocardiography demonstrated a mean gradient of 12 mmHg. At 12 months, the patient was in New York Heart Association class I, with preserved renal function and a mean gradient of 8 mmHg. Continuous pressure monitoring may support intraprocedural assessment and guide valve optimization when contrast exposure is being avoided in patients with renal dysfunction.

Subjects

Author keywords

aortic stenosishemodynamicsrenal dysfunctiontranscatheter aortic valve replacementvalve‐in‐valvezero contrast

Authors and institutions

  • Division of Cardiology, Teikyo University School of Medicine, Tokyo, Japan.

ORCID profiles: Mizuki Miura, Yusuke Watanabe, Ken Kozuma

Cite

APA

Miura, M., Watanabe, Y., Omiya, J., & Kozuma, K. (2026). Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.71010

Vancouver

Miura M, Watanabe Y, Omiya J, Kozuma K. Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.71010

BibTeX
@article{Miura2026,
  author = {Miura, Mizuki and Watanabe, Yusuke and Omiya, Jo and Kozuma, Ken},
  title = {Zero‐Contrast Transcatheter Aortic Valve‐in‐Valve Replacement Guided by Continuous Hemodynamic Monitoring},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.71010}
}
Start for free →