Abstract (original language)

Giant coronary artery ectasia with acute thrombotic occlusion presents a difficult interventional challenge because of the large thrombus burden, impaired washout, distal embolization, and lack of appropriately sized coronary stents. A 69‐year‐old woman presented with inferior ST‐segment elevation myocardial infarction caused by thrombotic subtotal occlusion of an approximately 8‐mm dominant right coronary artery (RCA). Primary percutaneous coronary intervention was complicated by recurrent thrombotic no‐reflow despite sequential balloon angioplasty, selective aspiration thrombectomy, large‐lumen aspiration, and intracoronary antiplatelet and fibrinolytic therapy. Intravascular ultrasound (IVUS) demonstrated extensive residual thrombus and a true vessel diameter substantially larger than available coronary stent platforms. Because balloon deflation repeatedly resulted in vessel collapse with persistent TIMI 0–1 flow and hemodynamic instability, a 5.0‐mm drug‐eluting stent was implanted as a bailout scaffold. Persistent proximal malapposition was subsequently improved using simultaneous inflation of 6.0‐ and 4.0‐mm noncompliant balloons, restoring TIMI 3 flow. Three days later, the patient developed a large left cerebellar intracranial hemorrhage requiring surgical evacuation and external ventricular drainage. Antithrombotic therapy was withheld and subsequently reintroduced in a staged, imaging‐guided manner. Follow‐up angiography and IVUS demonstrated preserved TIMI 3 flow, satisfactory stent expansion and apposition, and residual non‐flow‐limiting thrombotic material. This case highlights the limitations of conventional coronary stenting in giant ectatic arteries and the role of IVUS in guiding bailout stent optimization and follow‐up assessment. It also emphasizes the need to balance stent thrombosis against recurrent intracranial bleeding. A 69‐year‐old woman presented with inferior ST‐segment elevation myocardial infarction caused by thrombotic subtotal occlusion of an approximately 8‐mm dominant right coronary artery (RCA). Primary percutaneous coronary intervention was complicated by recurrent thrombotic no‐reflow despite sequential balloon angioplasty, selective aspiration thrombectomy, large‐lumen aspiration, and intracoronary antiplatelet and fibrinolytic therapy. Intravascular ultrasound (IVUS) demonstrated extensive residual thrombus and a true vessel diameter substantially larger than available coronary stent platforms. Because balloon deflation repeatedly resulted in vessel collapse with persistent TIMI 0–1 flow and hemodynamic instability, a 5.0‐mm drug‐eluting stent was implanted as a bailout scaffold. Persistent proximal malapposition was subsequently improved using simultaneous inflation of 6.0‐ and 4.0‐mm noncompliant balloons. TIMI 3 flow was restored. Three days later, the patient developed a large left cerebellar intracranial hemorrhage with fourth‐ventricular compression requiring suboccipital craniectomy, hematoma evacuation, and external ventricular drainage. Antithrombotic therapy was withheld and subsequently reintroduced in a staged, imaging‐guided manner. Follow‐up angiography and IVUS demonstrated preserved TIMI 3 flow, satisfactory stent expansion and apposition, and residual non‐flow‐limiting thrombotic material.

Subjects

Author keywords

aspiration thrombectomybailout stentingcoronary artery ectasiagiant coronary arteryintracranial hemorrhageintravascular ultrasoundthrombotic no‐reflow

Authors and institutions

  • Department of Cardiology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong.

ORCID profiles: Chee Kent Er

Cite

APA

Er, C. K., Chan, J. C. H., & Yau, K. H. (2026). When an 8‐mm Coronary Artery Has No Appropriate Stent: Bailout PCI and Dual‐Balloon Optimization in Giant Right Coronary Artery Ectasia. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70989

Vancouver

Er CK, Chan JCH, Yau KH. When an 8‐mm Coronary Artery Has No Appropriate Stent: Bailout PCI and Dual‐Balloon Optimization in Giant Right Coronary Artery Ectasia. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70989

BibTeX
@article{Er2026,
  author = {Er, Chee Kent and Chan, John C H and Yau, Kwok Ho},
  title = {When an 8‐mm Coronary Artery Has No Appropriate Stent: Bailout PCI and Dual‐Balloon Optimization in Giant Right Coronary Artery Ectasia},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70989}
}
Start for free →