EUVIMEDOpdag EUVIMED
FallberichtOpen access · CC BY-NC 4.0

When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout

Yuto Abe iD, Yuya Hirata, Fumimasa Tabata, Tomomi Koizumi

Catheterization and Cardiovascular Interventions · 2026-11 · 108 (6) · 2105-2109

DOI: 10.1002/ccd.70894 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, published online on 2026-09-16. Written by Yuto Abe and 3 co-authors. Institution: Department of Cardiovascular Medicine, National Hospital Organization Mito Medical Center, Ibaraki, Japan. Major MEDLINE topics: Angioplasty, Balloon, Coronary, Cardiac Catheterization, Coronary Artery Disease, Drug-Eluting Stents. 8 references. The full text is freely available (open access, CC BY-NC 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Incomplete stent apposition at the proximal coronary artery may predispose to subtle guiding catheter–induced stent deformation, creating a gap between the stent and the vessel wall that facilitates inadvertent abluminal guidewire passage. We report a case in which balloon dilatation over an unrecognized abluminal guidewire resulted in severe proximal stent deformation and was successfully managed by real‐time IVUS tip‐detection–guided rewiring into the true stent lumen, avoiding additional stent implantation. This case highlights the importance of careful guiding catheter manipulation, meticulous intravascular imaging assessment after guidewire crossing, and IVUS‐guided bailout techniques for the prevention, early recognition, and management of this potentially serious procedural complication.

Subjects

MeSH terms (MEDLINE)

Angioplasty, Balloon, CoronaryCardiac CatheterizationCoronary Artery DiseaseDrug-Eluting StentsProsthesis FailureStentsUltrasonography, InterventionalHumansMaleCardiac CathetersCoronary AngiographyProsthesis DesignTreatment Outcome

Author keywords

abluminal guidewire passageincomplete stent appositionintravascular ultrasoundpercutaneous coronary interventionstent deformation

Authors and institutions

  • Department of Cardiovascular Medicine, National Hospital Organization Mito Medical Center, Ibaraki, Japan.

ORCID profiles: Yuto Abe

Cite

APA

Abe, Y., Hirata, Y., Tabata, F., & Koizumi, T. (2026). When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout. Catheterization and Cardiovascular Interventions, 108(6), 2105-2109. https://doi.org/10.1002/ccd.70894

Vancouver

Abe Y, Hirata Y, Tabata F, Koizumi T. When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout. Catheterization and Cardiovascular Interventions. 2026;108(6):2105-2109. doi:10.1002/ccd.70894

BibTeX
@article{Abe2026,
  author = {Abe, Yuto and Hirata, Yuya and Tabata, Fumimasa and Koizumi, Tomomi},
  title = {When Subtle Guiding Catheter‐Induced Stent Deformation Leads to Abluminal Guidewire Passage: Successful IVUS Tip‐Detection‐Guided Bailout},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {6},
  pages = {2105--2109},
  doi = {10.1002/ccd.70894}
}
Start for free →