EUVIMEDEUVIMED entdecken
Open Access

Prosthesis‐Patient Mismatch in All‐Comer Patients Undergoing Newer‐Generation Self‐Expanding Transcatheter Aortic Valve Replacement

Xander Jacquemyn iD, Takuya Ogami iD, Irsa Hasan, Dustin Kliner, Derek Serna-Gallegos, Catalin Toma iD, Amber Makani, David West, Ibrahim Sultan

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70698 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Xander Jacquemyn und 8 weiteren Autor:innen. Beteiligte Einrichtung: UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Aortic Valve Stenosis, Transcatheter Aortic Valve Replacement, Aortic Valve. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Prosthesis‐patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) may affect outcomes, but its incidence and impact with contemporary self‐expanding valves remain unclear.

Aims

Evaluate the frequency, predictors, and long‐term outcomes of PPM in a real‐world TAVR population.

Methods

We analyzed patients ≥ 18 years undergoing TAVR with current‐generation self‐expanding valves (Evolut FX/FX+, PRO/PRO+, Navitor, Navitor Vision) from a prospectively maintained institutional database (2017–2025). Predicted PPM was defined according to VARC‐3 criteria, with all‐cause mortality and heart failure hospitalization as the primary outcomes.

Results

Among 2989 patients (median age 80 [75−85], 50.8% female) receiving Evolut (83.3%) or Navitor (16.7%) valves, PPM occurred in 5.0% (moderate 3.7%, severe 1.3%) and declined from 6.5% in 2017 to 2.7% in 2025 ( p = 0.002). Independent predictors of PPM included female sex (OR 2.04, 95% CI 1.06−3.99, p = 0.035) and valve‐in‐valve procedures (OR 9.60, 95% CI 3.82−25.64, p < 0.001), whereas use of the Navitor valve was associated with markedly lower odds (OR 0.07, 95% CI 0.00−0.32, p = 0.009). Patients with PPM demonstrated significantly higher post‐procedural transvalvular gradients and reduced aortic valve areas (both p < 0.001). PPM was not associated with adverse long‐term clinical outcomes, with no significant differences in 5‐year all‐cause mortality (HR 0.84, 95% CI 0.45−1.57, p = 0.592) or heart failure hospitalization (HR 1.22, 95% CI 0.84−1.77, p = 0.295).

Conclusion

In this contemporary TAVR cohort, PPM was infrequent, and its incidence declined over time. Female sex and valve‐in‐valve procedures independently predicted PPM. Despite adverse hemodynamic profiles, PPM was not associated with early or long‐term adverse clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisAortic Valve StenosisTranscatheter Aortic Valve ReplacementAortic ValveHumansFemaleProsthesis DesignMaleAged, 80 and overTreatment OutcomeRisk FactorsTime FactorsAgedRisk AssessmentDatabases, FactualRetrospective StudiesRecovery of FunctionHeart Failure

Stichwörter der Autor:innen

aortic stenosisprosthesis‐patient mismatchself‐expandingtranscatheter aortic valve replacementvalve‐in‐valve

Autor:innen und Institutionen

  • UPMC Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
  • Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

ORCID-Profile: Xander Jacquemyn, Takuya Ogami, Catalin Toma

Zitieren

APA

Jacquemyn, X., Ogami, T., Hasan, I., Kliner, D., Serna-Gallegos, D., Toma, C., Makani, A., West, D., & Sultan, I. (2026). Prosthesis‐Patient Mismatch in All‐Comer Patients Undergoing Newer‐Generation Self‐Expanding Transcatheter Aortic Valve Replacement. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70698

Vancouver

Jacquemyn X, Ogami T, Hasan I, Kliner D, Serna-Gallegos D, Toma C, et al. Prosthesis‐Patient Mismatch in All‐Comer Patients Undergoing Newer‐Generation Self‐Expanding Transcatheter Aortic Valve Replacement. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70698

BibTeX
@article{Jacquemyn2026,
  author = {Jacquemyn, Xander and Ogami, Takuya and Hasan, Irsa and Kliner, Dustin and Serna-Gallegos, Derek and Toma, Catalin and Makani, Amber and West, David and Sultan, Ibrahim},
  title = {Prosthesis‐Patient Mismatch in All‐Comer Patients Undergoing Newer‐Generation Self‐Expanding Transcatheter Aortic Valve Replacement},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70698}
}
Kostenlos starten →