EUVIMEDOpdag EUVIMED
FallberichtOpen access

Escalating Diameter Buddy Balloon in Transcatheter Aortic Valve Implantation With Complex Aortic Arch

Luca Paolucci iD, Mario Scarpelli, Daniele Maselli, Carlo Briguori

Catheterization and Cardiovascular Interventions · 2026-08 · 108 (2) · 640-643

DOI: 10.1002/ccd.70694 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, published online on 2026-06-14. Written by Luca Paolucci and 3 co-authors. Institution: Interventional Cardiology Unit, Mediterranea Cardiocentro, Naples, Italy. Major MEDLINE topics: Heart Valve Prosthesis Implantation, Aortic Valve Stenosis, Aorta, Thoracic, Aortic Valve. 10 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The buddy balloon technique facilitates transcatheter heart valve (THV) crossing the native aortic valve. Case Summary An 80‐year‐old female, with previous ascending aorta replacement and aortic valve replacement with bioprosthesis, was admitted to our hospital to undergo transcatheter aortic valve implantation due to bioprosthetic valve dysfunction. The self‐expandable Allegra 23 mm, advanced through the right femoral artery, got stuck at the point of passage between the aortic arch and the prosthetic tube in the ascending aorta. A peripheral balloon was advanced from the left femoral artery and simultaneously inflated at the stalemate point, while pushing the valve toward the implantation site. Following failure with 5 mm and 7 mm balloons, crossing was successful with a 9 mm balloon.

Discussion

The standard buddy balloon technique involves the use of a single balloon diameter. Herein, we propose an escalating approach to increase chances of success and prevent potential complications, such as vessel rupture. Take Home Message The “escalating diameter” buddy balloon technique represents a safe and effective exit‐strategy in case of challenges in advancing the THV system.

Subjects

MeSH terms (MEDLINE)

Heart Valve Prosthesis ImplantationAortic Valve StenosisAorta, ThoracicAortic ValveBalloon ValvuloplastyCardiac CatheterizationProsthesis FailureTranscatheter Aortic Valve ReplacementHumansFemaleAged, 80 and overHeart Valve ProsthesisTreatment OutcomeProsthesis DesignBioprosthesisAortography

Authors and institutions

  • Interventional Cardiology Unit, Mediterranea Cardiocentro, Naples, Italy.
  • Cardiac Surgey Unit, Mediterranea Cardiocentro, Naples, Italy.

ORCID profiles: Luca Paolucci

Cite

APA

Paolucci, L., Scarpelli, M., Maselli, D., & Briguori, C. (2026). Escalating Diameter Buddy Balloon in Transcatheter Aortic Valve Implantation With Complex Aortic Arch. Catheterization and Cardiovascular Interventions, 108(2), 640-643. https://doi.org/10.1002/ccd.70694

Vancouver

Paolucci L, Scarpelli M, Maselli D, Briguori C. Escalating Diameter Buddy Balloon in Transcatheter Aortic Valve Implantation With Complex Aortic Arch. Catheterization and Cardiovascular Interventions. 2026;108(2):640-643. doi:10.1002/ccd.70694

BibTeX
@article{Paolucci2026,
  author = {Paolucci, Luca and Scarpelli, Mario and Maselli, Daniele and Briguori, Carlo},
  title = {Escalating Diameter Buddy Balloon in Transcatheter Aortic Valve Implantation With Complex Aortic Arch},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {2},
  pages = {640--643},
  doi = {10.1002/ccd.70694}
}
Start for free →