EUVIMEDScopri EUVIMED
Multizentrische StudieBeobachtungsstudieOpen access

Prognostic Impact of Pacemaker Implantation in Transcatheter Aortic Valve Replacement With Self‐Expanding Prosthesis

Francesco De Felice iD, Luca Paolucci iD, Marco Stefano Nazzaro, Carmine Musto, Diana Chin, Rocco Stio, Mauro Pennacchi, Domenico Gabrielli, Mauro Massussi iD, Giuliano Chizzolla, Marianna Adamo, Marco De Carlo iD and 13 more

Catheterization and Cardiovascular Interventions · 2026-08 · 108 (2) · 314-322

DOI: 10.1002/ccd.70652 ↗

At a glance

Multizentrische Studie in Catheterization and Cardiovascular Interventions, published online on 2026-05-12. Written by Francesco De Felice and 24 co-authors. Institution: Division of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy. Major MEDLINE topics: Aortic Valve, Aortic Valve Stenosis, Arrhythmias, Cardiac, Bioprosthesis. 27 references. The full text is freely available in PubMed Central.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

With the progressively increasing number of low‐risk patients undergoing transcatheter aortic valve replacement (TAVR), the number of those who will be long‐time pacemaker (PM) carriers is expected to increase. To date, conflicting data is available regarding the association between PM and mortality following TAVR.

Aims

To investigate the association between PM and mortality in patients undergoing TAVR with self‐expandable bio‐prosthesis.

Methods

Patients undergoing TAVR between 2007 and 2014 in 10 Italian centers were considered. Two analyses were performed: one comparing patients with and without pre‐TAVR PM (primary) and one comparing those with and without post‐TAVR PM (secondary). The primary endpoint was all‐cause mortality; the secondary endpoint was re‐hospitalization to the cardiac ward. Clinical outcomes were assessed at the longest available follow‐up.

Results

Overall, 1779 patients were included in the primary analysis and 1465 in the secondary one. Pre‐TAVR PM implantation was not associated with an increased risk of all cause death in both the primary (adj. HR 0.93, 95% CI 0.76−1.13; p = 0.475) and secondary analysis (adj. HR 0.83, 95% CI 0.71−0.98; p = 0.029). Regarding hospitalization to cardiac ward, pre‐TAVR PM was not associated with the outcome (adj. HR 1.10, 95% CI 0.85−1.42, p = 0.254), while post‐TAVR PM implantation was related with an increased risk (adj. HR 1.94, 95% CI 1.56−2.41; p < 0.001).

Conclusions

PM implantation is not associated with an increased risk of mortality in patients undergoing TAVR.

Subjects

MeSH terms (MEDLINE)

Aortic ValveAortic Valve StenosisArrhythmias, CardiacBioprosthesisCardiac Pacing, ArtificialHeart Valve ProsthesisPacemaker, ArtificialTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMaleItalyPatient ReadmissionProsthesis DesignRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTreatment Outcome

Author keywords

TAVRmortalitypacemaker

Authors and institutions

  • Division of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
  • Cardiac Catheterization Laboratory and Cardiology, ASST Spedali Civili di Brescia, Brescia, Italy.
  • Institute of Cardiology, ASST Spedali Civili di Brescia, Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy.
  • Interventional Cardiology Section, Cardiothoracic and Vascular Department, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.
  • Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy.
  • School of Medicine, Vita-Salute San Raffaele University, Milan, Italy.

ORCID profiles: Francesco De Felice, Luca Paolucci, Mauro Massussi, Marco De Carlo, Antonio Sisinni, Luca Testa, Matteo Montorfano, Tiziana Attisano

Cite

APA

Felice, F., Paolucci, L., Nazzaro, M. S., Musto, C., Chin, D., Stio, R., Pennacchi, M., Gabrielli, D., Massussi, M., Chizzolla, G., Adamo, M., Carlo, M., Giannini, C., Costa, G., Sisinni, A., Testa, L., Bellini, B., Montorfano, M., Bruschi, G., …, & Regazzoli, D. (2026). Prognostic Impact of Pacemaker Implantation in Transcatheter Aortic Valve Replacement With Self‐Expanding Prosthesis. Catheterization and Cardiovascular Interventions, 108(2), 314-322. https://doi.org/10.1002/ccd.70652

Vancouver

Felice F, Paolucci L, Nazzaro MS, Musto C, Chin D, Stio R, et al. Prognostic Impact of Pacemaker Implantation in Transcatheter Aortic Valve Replacement With Self‐Expanding Prosthesis. Catheterization and Cardiovascular Interventions. 2026;108(2):314-322. doi:10.1002/ccd.70652

BibTeX
@article{Felice2026,
  author = {Felice, Francesco De and Paolucci, Luca and Nazzaro, Marco Stefano and Musto, Carmine and Chin, Diana and Stio, Rocco and Pennacchi, Mauro and Gabrielli, Domenico and Massussi, Mauro and Chizzolla, Giuliano and Adamo, Marianna and Carlo, Marco De and Giannini, Cristina and Costa, Giulia and Sisinni, Antonio and Testa, Luca and Bellini, Barbara and Montorfano, Matteo and Bruschi, Giuseppe and Merlanti, Bruno and Poli, Arnaldo and Ferrara, Erica and Attisano, Tiziana and Palmerini, Tullio and Regazzoli, Damiano},
  title = {Prognostic Impact of Pacemaker Implantation in Transcatheter Aortic Valve Replacement With Self‐Expanding Prosthesis},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  volume = {108},
  number = {2},
  pages = {314--322},
  doi = {10.1002/ccd.70652}
}
Start for free →