The Influence of Radiographic Equipment, Setup, and Operator Experience on Radiation Exposure in Chronic Total Occlusion Interventions
Catheterization and Cardiovascular Interventions · 2025-10 · 106 (4) · 2734-2743
DOI: 10.1002/ccd.70126 ↗At a glance
Multizentrische Studie in Catheterization and Cardiovascular Interventions, published online on 2025-08-25. Written by Gerald S Werner and 25 co-authors. Institution: University Heart & Vascular Centre, Frankfurt, Germany. Major MEDLINE topics: Radiation Exposure, Coronary Occlusion, Radiation Dosage, Radiography, Interventional. Cited 1 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY 4.0). Funded by: The authors received no specific funding for this work..
Abstract (original language)
Background
High radiation exposure is a significant risk with recanalizations for chronic total coronary occlusions (CTO).
Aims
To analyze the influence of radiographic equipment, radiation protocols, and operator experience on radiation exposure.
Methods
We analyzed 17,769 procedures by 27 operators from a multicenter European Registry between 2015 and 2023. Thirteen operators had an experience > 10 years (Gen1), and 14 entered the registry after 2015 (Gen2). AirKerma (AK), dose area product (DAP), the dose rate index (DRI) as AK per fluoroscopy time (FT), and the collimation index (CLI) as DAP per AK were calculated to assess inter‐operator variability.
Results
Despite increased lesion complexity (2015−17: CASTLE score 1.83 ± 1.10, 2021−23: 2.20 ± 1.19; p < 0.001), AK and DAP were reduced by 45%. Gen1 operators treated more complex lesions than Gen 2 (2.05 ± 1.13 vs. 1.85 ± 1.16; p < 0.001) at more extended FT (38.4 [23−61] vs. 34.0 [20−57]; p < 0.001) than Gen2 with slightly higher AK (1.6 [0.89−2.8] Gy vs. 1.4 [0.8−2.54]; p < 0.001), but DRI was similar (42.9 [27.7−64.3] vs. [28.0−62.1]). In 2015−17, operators with Philips Clarity had a lower median AK (1.7 Gy; p < 0.001) than other vendors (Siemens 2.1 Gy; General Electric 2.8 Gy), but with updated equipment, Philips systems had slightly higher AK (1.2 Gy) than Siemens systems (1.0 Gy; p < 0.001). Inter‐operator variability regarding DRI improved over time, but collimation did not change.
Conclusions
Radiation exposure for CTO PCI was reduced for both long‐time and recent CTO operators during 9 years. Equipment updates were instrumental to improved radiation management, but inter‐operator differences remained regarding dose management and collimation.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- University Heart & Vascular Centre, Frankfurt, Germany.
- Centre hospitalier de Valenciennes, Valenciennes, France.
- Clinique Saint Augustin, Bordeaux, France.
- Hôpital Privé La Louvière, Lille, France.
- Praxisklinik Herz & Gefaesse, Dresden, Germany.
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano-Milan, Italy.
ORCID profiles: Gerald S Werner, Nicolas Boudou, Gabriele Gasparini, Maciej Lesiak, Evald H Christiansen, Kambis Mashayekhi
Funding
- The authors received no specific funding for this work.
Cite
APA
Werner, G. S., Avran, A., Boudou, N., Leroy, F., Dalibor, J., Gasparini, G., Bufe, A., Bryniarski, L., Lesiak, M., La Manna, A., Dens, J., Stojkovic, S., Ledermann, B., Christiansen, E. H., Furkalo, S., Kalnins, A., Ladwiniec, A., La Scala, E., Bozinovic, N., …, & Mashayekhi, K. (2025). The Influence of Radiographic Equipment, Setup, and Operator Experience on Radiation Exposure in Chronic Total Occlusion Interventions. Catheterization and Cardiovascular Interventions, 106(4), 2734-2743. https://doi.org/10.1002/ccd.70126
Vancouver
Werner GS, Avran A, Boudou N, Leroy F, Dalibor J, Gasparini G, et al. The Influence of Radiographic Equipment, Setup, and Operator Experience on Radiation Exposure in Chronic Total Occlusion Interventions. Catheterization and Cardiovascular Interventions. 2025;106(4):2734-2743. doi:10.1002/ccd.70126
BibTeX
@article{Werner2025,
author = {Werner, Gerald S and Avran, Alexandre and Boudou, Nicolas and Leroy, Fabrice and Dalibor, Joerg and Gasparini, Gabriele and Bufe, Alexander and Bryniarski, Leszek and Lesiak, Maciej and La Manna, Alessio and Dens, Jo and Stojkovic, Sinisa and Ledermann, Bertrand and Christiansen, Evald H and Furkalo, Sergey and Kalnins, Artis and Ladwiniec, Andrew and La Scala, Eugenio and Bozinovic, Nenad and Wojcik, Jaroslaw and Lange, Artur and Lismanis, Aigars and Vlachojannis, Marios and Hildick-Smith, David and Grancini, Luca and Mashayekhi, Kambis},
title = {The Influence of Radiographic Equipment, Setup, and Operator Experience on Radiation Exposure in Chronic Total Occlusion Interventions},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
volume = {106},
number = {4},
pages = {2734--2743},
doi = {10.1002/ccd.70126}
}
EUVIMED