EUVIMEDEUVIMED entdecken
Multizentrische StudieVergleichsstudie

Institutional Variation in Patient Radiation Doses During Transcatheter Valve Interventions

David A McNamara, Jeremy Albright, Devraj Sukul, Stanley Chetcuti, Annemarie Forrest, Paul Grossman, Raed M Alnajjar, Himanshu Patel, Hitinder S Gurm, Ryan D Madder

JACC: Cardiovascular Interventions · 2024

DOI: 10.1016/j.jcin.2024.08.048 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift JACC: Cardiovascular Interventions, 2024. Verfasst von David A McNamara und 9 weiteren Autor:innen. Beteiligte Einrichtung: Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan, USA. Electronic address: david.mcnamara@corewellhealth.org. Hauptthemen laut MEDLINE: Radiation Dosage, Radiation Exposure, Transcatheter Aortic Valve Replacement. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Little is known about institutional radiation doses during transcatheter valve interventions. OBJECTIVES: The authors sought to evaluate institutional variability in radiation doses during transcatheter valve interventions. METHODS: Using a large statewide registry, transcatheter edge-to-edge mitral valve repair, transcatheter mitral valve replacement, and transcatheter aortic valve replacement procedures between January 1, 2020, and December 31, 2022, with an air kerma (AK) recorded were analyzed. Patient and procedural characteristics were compared between cases with AK ≥2 and

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageRadiation ExposureTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMaleMiddle AgedBayes TheoremCardiac CatheterizationHeart Valve DiseasesHeart Valve Prosthesis ImplantationHospitalsRadiography, InterventionalRegistriesRetrospective StudiesRisk AssessmentRisk FactorsTime FactorsTreatment Outcome

Stichwörter der Autor:innen

TAVRTEERTMVRoccupational radiationradiation safetytranscatheter aortic valve replacementtranscatheter edge-to-edge mitral valve repairtranscatheter mitral valve replacement

Autor:innen und Institutionen

  • Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan, USA. Electronic address: david.mcnamara@corewellhealth.org.
  • Department of Internal Medicine, Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Cardiothoracic Surgery, Henry Ford Macomb, Clinton Township, Michigan, USA.
  • Frederik Meijer Heart & Vascular Institute, Corewell Health West, Grand Rapids, Michigan, USA.

Zitieren

APA

McNamara, D. A., Albright, J., Sukul, D., Chetcuti, S., Forrest, A., Grossman, P., Alnajjar, R. M., Patel, H., Gurm, H. S., & Madder, R. D. (2024). Institutional Variation in Patient Radiation Doses During Transcatheter Valve Interventions. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2024.08.048

Vancouver

McNamara DA, Albright J, Sukul D, Chetcuti S, Forrest A, Grossman P, et al. Institutional Variation in Patient Radiation Doses During Transcatheter Valve Interventions. JACC: Cardiovascular Interventions. 2024. doi:10.1016/j.jcin.2024.08.048

BibTeX
@article{McNamara2024,
  author = {McNamara, David A and Albright, Jeremy and Sukul, Devraj and Chetcuti, Stanley and Forrest, Annemarie and Grossman, Paul and Alnajjar, Raed M and Patel, Himanshu and Gurm, Hitinder S and Madder, Ryan D},
  title = {Institutional Variation in Patient Radiation Doses During Transcatheter Valve Interventions},
  journal = {JACC: Cardiovascular Interventions},
  year = {2024},
  doi = {10.1016/j.jcin.2024.08.048}
}
Kostenlos starten →