Balloon‐Expandable Versus Self‐Expanding Valves in Bicuspid Aortic Stenosis: Insights From the SWEDEHEART Registry
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70073 ↗At a glance
Beobachtungsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Antros Louca and 13 co-authors. Institution: Department of Cardiology, Sahlgrenska University Hospital, Gothenburg, Sweden. Major MEDLINE topics: Aortic Valve Stenosis, Heart Valve Prosthesis, Bicuspid Aortic Valve Disease, Aortic Valve. Cited 1 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: A.L. has received funds through the Gothenburg Society of Medicine (1000894 and 1021054). T.R. has received funds through the Swedish Heart and Lung Foundation….
Abstract (original language)
Background
Transcatheter aortic valve replacement (TAVR) is increasingly used in patients with bicuspid aortic valve (BAV) stenosis, but there is limited comparative data on balloon‐expandable (BEV) versus self‐expanding valves (SEV) in this population.
Aim
To compare clinical and hemodynamic outcomes between BEVs and SEVs in patients with BAV stenosis.
Methods
This observational cohort included all patients who underwent TAVR in Sweden between 2016 and 2022. Exclusion criteria included procedures for pure aortic insufficiency and valve‐in‐valve interventions. The analysis focused on Evolut, Sapien, Acurate, and Portico/Navitor valve families. A doubly robust approach was applied combining inverse probability of treatment weighting and multivariable regression. Sensitivity analyses were also conducted.
Results
Of 577 patients, 274 (47.5%) received a BEV. The majority in the SEV group received an Evolut valve (62%). The mean EUROSCORE II‐predicted mortality risk was 4.1% for BEV and 3.6% for SEV. BEVs were used more in patients with reduced ejection fraction (EF ≤ 40%) and larger aortic annuli. There were no significant differences between groups in periprocedural mortality, all‐cause mortality at a median follow‐up of 675 days, or device success. However, SEVs had higher technical success (aOR: 2.21, p = 0.006), lower postprocedural gradients (adjusted coefficient: −3.72, p < 0.001), and reduced risk of prosthesis‐patient mismatch (aOR: 0.10, p = 0.02). SEVs, though, had a higher incidence of paravalvular leakage (aOR: 7.5, p < 0.01).
Conclusion
Both BEVs and SEVs were feasible with similar clinical outcomes in BAV stenosis. SEVs had better hemodynamic outcomes but more paravalvular leakage. Randomized trials are needed to determine the optimal valve choice.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Sahlgrenska University Hospital, Gothenburg, Sweden.
- Department of Molecular and Clinical Medicine, Institute of Medicine, University of Gothenburg, Gothenburg, Sweden.
- Heart Centre, Umeå University Hospital, Umeå, Sweden.
- Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden.
- Department of Cardiology, Karolinska University Hospital and Karolinska Institutet, Stockholm, Sweden.
- Department of Medical Sciences, Cardiology, Uppsala University, Uppsala, Sweden.
ORCID profiles: Antros Louca, Joakim Sundström, Stefan James, Oskar Angerås
Funding
- A.L. has received funds through the Gothenburg Society of Medicine (1000894 and 1021054). T.R. has received funds through the Swedish Heart and Lung Foundation…
Cite
APA
Louca, A., Sundström, J., Rawshani, A., Hagström, H., Settergren, M., James, S., Koul, S., Skoglund, K., Ioanes, D., Völz, S., Myredal, A., Angerås, O., Petursson, P., & Råmunddal, T. (2025). Balloon‐Expandable Versus Self‐Expanding Valves in Bicuspid Aortic Stenosis: Insights From the SWEDEHEART Registry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70073
Vancouver
Louca A, Sundström J, Rawshani A, Hagström H, Settergren M, James S, et al. Balloon‐Expandable Versus Self‐Expanding Valves in Bicuspid Aortic Stenosis: Insights From the SWEDEHEART Registry. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70073
BibTeX
@article{Louca2025,
author = {Louca, Antros and Sundström, Joakim and Rawshani, Araz and Hagström, Henrik and Settergren, Magnus and James, Stefan and Koul, Sasha and Skoglund, Kristofer and Ioanes, Dan and Völz, Sebastian and Myredal, Anna and Angerås, Oskar and Petursson, Petur and Råmunddal, Truls},
title = {Balloon‐Expandable Versus Self‐Expanding Valves in Bicuspid Aortic Stenosis: Insights From the SWEDEHEART Registry},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70073}
}
EUVIMED