Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Roel Hoek and 12 co-authors. Institution: Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands. Major MEDLINE topics: Fractional Flow Reserve, Myocardial, Myocardial Perfusion Imaging, Saphenous Vein, Coronary Artery Bypass. 39 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: The authors received no specific funding for this work..
Abstract (original language)
Background
Revascularization decision‐making for saphenous vein grafts (SVGs) relies on angiographic lesion severity estimation, as studies on fractional flow reserve (FFR) for detecting ischemia in SVGs are scarce.
Aims
To compare FFR and quantitative coronary angiography (QCA) of SVGs against myocardial perfusion imaging (MPI) and to establish an optimal FFR threshold for SVGs.
Methods
This cross‐sectional registry study included symptomatic patients with prior coronary artery bypass grafting who underwent single‐photon emission computed tomography, positron emission tomography, or stress perfusion cardiac magnetic resonance imaging and had FFR measurements of ≥ 1 SVGs. We matched the myocardial territory supplied by the SVGs to ischemia on MPI. The optimal FFR threshold for SVGs was determined using the Youden index. Diagnostic performance measures were calculated and compared for FFR (0.80 and the optimal threshold) and for QCA (diameter stenosis ≥ 50%).
Results
This study included 80 patients (mean age 73 ± 7 years, 68 [85%] male) with 94 SVGs, of which 38 (40%) supplied ischemic myocardium. Areas under the curve between FFR and QCA were comparable (0.73 vs. 0.65, p = 0.181). The optimal cutoff value of FFR was 0.94. FFR ≤ 0.94 showed higher sensitivity (63%) and negative predictive value (75%) compared to FFR ≤ 0.80 (32% [ p < 0.001] and 64% [ p = 0.007]) and QCA (37% [ p = 0.002] and 65% [ p = 0.021]), but with lower specificity (75%) than FFR ≤ 0.80 (84%, p = 0.021). Positive predictive value and overall accuracy were similar across all methods.
Conclusions
FFR and QCA had comparable moderate diagnostic performance for detecting SVG failure determined by MPI. The optimal FFR cutoff in SVGs is higher than 0.80, resulting in higher sensitivity and negative predictive value compared to FFR ≤ 0.80 and QCA, at the expense of reduced specificity.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
- Department of Epidemiology & Data Science, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
- Department of Radiology & Nuclear Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
- Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands.
- Department of Cardiology, Northwest Clinics, Alkmaar, The Netherlands.
ORCID profiles: Roel Hoek, Yvemarie B O Somsen, Pepijn A van Diemen, Paul Knaapen
Funding
- The authors received no specific funding for this work.
Cite
APA
Hoek, R., de Winter, R. W., Peters, R. T., Somsen, Y. B. O., van Diemen, P. A., Jukema, R. A., Twisk, J. W., Verouden, N. J., den Hartog, A. W., Raijmakers, P. G., Nap, A., Danad, I., & Knaapen, P. (2025). Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31467
Vancouver
Hoek R, de Winter RW, Peters RT, Somsen YBO, van Diemen PA, Jukema RA, et al. Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31467
BibTeX
@article{Hoek2025,
author = {Hoek, Roel and de Winter, Ruben W and Peters, Rens T and Somsen, Yvemarie B O and van Diemen, Pepijn A and Jukema, Ruurt A and Twisk, Jos W and Verouden, Niels J and den Hartog, Alexander W and Raijmakers, Pieter G and Nap, Alexander and Danad, Ibrahim and Knaapen, Paul},
title = {Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31467}
}
EUVIMED