Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Roel Hoek und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Myocardial Perfusion Imaging, Saphenous Vein, Coronary Artery Bypass. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Revascularization decision‐making for saphenous vein grafts (SVGs) relies on angiographic lesion severity estimation, as studies on fractional flow reserve (FFR) for detecting ischemia in SVGs are scarce.

Aims

To compare FFR and quantitative coronary angiography (QCA) of SVGs against myocardial perfusion imaging (MPI) and to establish an optimal FFR threshold for SVGs.

Methods

This cross‐sectional registry study included symptomatic patients with prior coronary artery bypass grafting who underwent single‐photon emission computed tomography, positron emission tomography, or stress perfusion cardiac magnetic resonance imaging and had FFR measurements of ≥ 1 SVGs. We matched the myocardial territory supplied by the SVGs to ischemia on MPI. The optimal FFR threshold for SVGs was determined using the Youden index. Diagnostic performance measures were calculated and compared for FFR (0.80 and the optimal threshold) and for QCA (diameter stenosis ≥ 50%).

Results

This study included 80 patients (mean age 73 ± 7 years, 68 [85%] male) with 94 SVGs, of which 38 (40%) supplied ischemic myocardium. Areas under the curve between FFR and QCA were comparable (0.73 vs. 0.65, p = 0.181). The optimal cutoff value of FFR was 0.94. FFR ≤ 0.94 showed higher sensitivity (63%) and negative predictive value (75%) compared to FFR ≤ 0.80 (32% [ p < 0.001] and 64% [ p = 0.007]) and QCA (37% [ p = 0.002] and 65% [ p = 0.021]), but with lower specificity (75%) than FFR ≤ 0.80 (84%, p = 0.021). Positive predictive value and overall accuracy were similar across all methods.

Conclusions

FFR and QCA had comparable moderate diagnostic performance for detecting SVG failure determined by MPI. The optimal FFR cutoff in SVGs is higher than 0.80, resulting in higher sensitivity and negative predictive value compared to FFR ≤ 0.80 and QCA, at the expense of reduced specificity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialMyocardial Perfusion ImagingSaphenous VeinCoronary Artery BypassCoronary AngiographyTomography, Emission-Computed, Single-PhotonCoronary StenosisGraft Occlusion, VascularCoronary Artery DiseaseHumansMaleFemaleAgedPredictive Value of TestsCross-Sectional StudiesRegistriesMiddle AgedPositron-Emission TomographySeverity of Illness IndexReproducibility of ResultsAged, 80 and overMagnetic Resonance Imaging

Stichwörter der Autor:innen

coronary artery bypass graftingcoronary artery diseasefractional flow reservemyocardial perfusion imagingsaphenous vein graft

Autor:innen und Institutionen

  • Department of Cardiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • Department of Epidemiology & Data Science, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • Department of Radiology & Nuclear Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • Department of Cardiology, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Department of Cardiology, Northwest Clinics, Alkmaar, The Netherlands.

ORCID-Profile: Roel Hoek, Yvemarie B O Somsen, Pepijn A van Diemen, Paul Knaapen

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Hoek, R., de Winter, R. W., Peters, R. T., Somsen, Y. B. O., van Diemen, P. A., Jukema, R. A., Twisk, J. W., Verouden, N. J., den Hartog, A. W., Raijmakers, P. G., Nap, A., Danad, I., & Knaapen, P. (2025). Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31467

Vancouver

Hoek R, de Winter RW, Peters RT, Somsen YBO, van Diemen PA, Jukema RA, et al. Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31467

BibTeX
@article{Hoek2025,
  author = {Hoek, Roel and de Winter, Ruben W and Peters, Rens T and Somsen, Yvemarie B O and van Diemen, Pepijn A and Jukema, Ruurt A and Twisk, Jos W and Verouden, Niels J and den Hartog, Alexander W and Raijmakers, Pieter G and Nap, Alexander and Danad, Ibrahim and Knaapen, Paul},
  title = {Comparison of Fractional Flow Reserve and Myocardial Perfusion Imaging in Saphenous Vein Grafts},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31467}
}
Kostenlos starten →