EUVIMEDEUVIMED entdecken
Multizentrische Studie

Clinical Value of CT‐Based 3D Computational Modeling in Left Atrial Appendage Occlusion: An In‐Depth Analysis of the PRECISE LAAO Study

Emmanuel De Cock iD, Stijn Lochy, Maximo Rivero-Ayerza, Mathieu Lempereur, Kristoff Cornelis, Philippe Debonnaire, Paul Vermeersch iD, Emma Christiaen, Ian Buysschaert

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31464 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Emmanuel De Cock und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, AZ Sint-Jan Brugge AV, Brugge, Belgium. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Patient-Specific Modeling, Cardiac Catheterization. Die Arbeit nennt 14 Literaturangaben. Gefördert von: The authors thank Christian Vincent and Alessandro Bavo from FEops for their collaboration and rapid turnover in case simulations. This investigator-initiated….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Standard of care (SoC) assessment based on computed tomography (CT) and/or transesophageal echocardiography is suboptimal for adequate preprocedural evaluation for left atrial appendage occlusion (LAAO). This can be improved through CT‐based 3D computational modeling of the LAA‐device interaction using FEops HEARTguide. This study aims to assess the decisional impact of FEops in preprocedural planning for LAAO.

Methods

The PRECISE LAAO is a prospective multi‐center self‐controlled study evaluating the use of FEops in LAAO with Amulet. Preprocedural device size selection and degree of certainty (scale 0−10) were registered before (Decision SoC) and after accessing FEops (Decision FEops), followed by device implantation. Concordance was compared between the Decisions and the final implanted device. After the procedure, clinicians rated the subjective value of FEops on a scale from −3 (futile) to +3 (most helpful).

Results

One hundred two patients were included. Decision SoC was concordant with the implanted device in 61 patients (59.8%), whereas Decision FEops was concordant in 92 (90.2%, p < 0.0001). FEops induced a size change in 35 patients, which was correct in 33 (32.4%). Certainty SoC was 6.7 ± 1.3 and increased after FEops assessment to 7.6 ± 1.3 ( p < 0.0001). In the 33 patients with FEops‐induced positive corrections, Certainty SoC was lower (6.2 ± 1.5, suggesting a more complex procedure) and increased to 7.2 ± 1.2 with FEops ( p = 0.004). Clinicians rated FEops as helpful (subjective score ≥ 1) in 90.2% of cases.

Conclusions

CT‐based computational modeling using FEops has a positive decisional impact in LAAO, inducing a change in Amulet size selection in almost one out of three patients and increasing procedural confidence. Trials Trial Registration: NCT04640051.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial AppendageAtrial FibrillationPatient-Specific ModelingCardiac CatheterizationModels, CardiovascularRadiographic Image Interpretation, Computer-AssistedMultidetector Computed TomographyTomography, X-Ray ComputedHumansProspective StudiesMaleAgedFemalePredictive Value of TestsTreatment OutcomeAged, 80 and overClinical Decision-MakingProsthesis DesignEchocardiography, TransesophagealMiddle Aged

Stichwörter der Autor:innen

LAA closureMSCTatrial fibrillationclinical researchcomputational modeling

Autor:innen und Institutionen

  • Department of Cardiology, AZ Sint-Jan Brugge AV, Brugge, Belgium.
  • Department of Cardiology, Ghent University Hospital, Ghent, Belgium.
  • Department of Cardiology, UZ Brussel, Brussel, Belgium.
  • Department of Cardiology, Ziekenhuis Oost-Limburg (ZOL), Genk, Belgium.
  • Department of Cardiology, CHU de Liège, Liège, Belgium.
  • Department of Cardiology, AZ Maria Middelares, Gent, Belgium.

ORCID-Profile: Emmanuel De Cock, Paul Vermeersch

Förderung

  • The authors thank Christian Vincent and Alessandro Bavo from FEops for their collaboration and rapid turnover in case simulations. This investigator-initiated…

Zitieren

APA

De Cock, E., Lochy, S., Rivero-Ayerza, M., Lempereur, M., Cornelis, K., Debonnaire, P., Vermeersch, P., Christiaen, E., & Buysschaert, I. (2025). Clinical Value of CT‐Based 3D Computational Modeling in Left Atrial Appendage Occlusion: An In‐Depth Analysis of the PRECISE LAAO Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31464

Vancouver

De Cock E, Lochy S, Rivero-Ayerza M, Lempereur M, Cornelis K, Debonnaire P, et al. Clinical Value of CT‐Based 3D Computational Modeling in Left Atrial Appendage Occlusion: An In‐Depth Analysis of the PRECISE LAAO Study. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31464

BibTeX
@article{DeCock2025,
  author = {De Cock, Emmanuel and Lochy, Stijn and Rivero-Ayerza, Maximo and Lempereur, Mathieu and Cornelis, Kristoff and Debonnaire, Philippe and Vermeersch, Paul and Christiaen, Emma and Buysschaert, Ian},
  title = {Clinical Value of CT‐Based 3D Computational Modeling in Left Atrial Appendage Occlusion: An In‐Depth Analysis of the PRECISE LAAO Study},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31464}
}
Kostenlos starten →