EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Anatomical and Imaging Predictors of Peri‐Device Leak Following Left Atrial Appendage Closure Using the LAmbre Device: A Comparative Study of CCTA and TEE

Genling Shi, Junyin Gu, Zhiyong Duan, Bin Wang, Mengshi Xie, Zhenzhou Zhang, Xixi Dai, Zhong Xu, Weifeng Yao, Yunfei Liu, Hongyu Shi iD

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70736 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Genling Shi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Left Atrial Appendage Closure, Echocardiography, Transesophageal, Atrial Fibrillation, Computed Tomography Angiography. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Natural Science Foundation of Shanghai, Key Project of the Science and Technology Committee of Baoshan District Shanghai, Shanghai Baoshan District Medical and Health Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Peri‐device leak (PDL) is a recognized finding following left atrial appendage closure (LAAC) and may influence device efficacy. Transesophageal echocardiography (TEE) is routinely used for surveillance but may have limited sensitivity for small or concealed leaks. Cardiac computed tomography angiography (CCTA) provides high spatial resolution and three‐dimensional reconstruction. This study compared CCTA and TEE for PDL detection after LAAC with the LAmbre device and examined anatomical distribution and evolution.

Methods

Eighty‐two consecutive patients with nonvalvular atrial fibrillation underwent successful LAmbre implantation between 2018 and 2020 and were followed for 12 ± 1.2 months. At 3 months, all patients underwent TEE and contrast‐enhanced CCTA. PDL was defined using attenuation‐based criteria on CCTA. Procedural characteristics, including cover disk position and repositioning attempts, were analyzed in relation to PDL.

Results

At 3 months, CCTA identified PDL in 30 patients (36.6%), whereas TEE detected PDL in 15 patients (18.3%). Most leaks were localized to the pulmonary vein–mitral valve region. PDL occurred more frequently when the cover disk was positioned external to the pulmonary vein ridge compared with intraridge placement (64.3% vs. 22.2%; odds ratio 6.30, 95% CI 2.31–17.20; p = 0.048). All leaks measured < 5 mm. At 12 months, persistent PDL was observed in five patients (6.1%).

Conclusion

CCTA identified more small PDL than TEE at early follow‐up. Cover disk positioning relative to the pulmonary vein ridge was associated with PDL. Our findings should be interpreted in the context of the retrospective, single‐center design and limited event numbers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Left Atrial Appendage ClosureEchocardiography, TransesophagealAtrial FibrillationComputed Tomography AngiographyAtrial AppendageSeptal Occluder DeviceHumansPredictive Value of TestsFemaleTime FactorsMaleTreatment OutcomeAgedRetrospective StudiesProsthesis DesignRisk FactorsAged, 80 and over

Stichwörter der Autor:innen

cardiac computed tomography angiographycover disk positionleft atrial appendage closurenonvalvular atrial fibrillationperi‐device leak

Autor:innen und Institutionen

  • Department of Cardiology, Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China.
  • Department of Radiology, Zhongshan Hospital Wusong Branch, Fudan University, Shanghai, China.

ORCID-Profile: Hongyu Shi

Förderung

  • Natural Science Foundation of Shanghai
  • Key Project of the Science and Technology Committee of Baoshan District Shanghai
  • Shanghai Baoshan District Medical and Health Project
  • Funded by Baoshan District Health Commission Talents (Excellent Academic Leaders) Program
  • Natural Science Foundation of Shanghai Municipality

Zitieren

APA

Shi, G., Gu, J., Duan, Z., Wang, B., Xie, M., Zhang, Z., Dai, X., Xu, Z., Yao, W., Liu, Y., & Shi, H. (2026). Anatomical and Imaging Predictors of Peri‐Device Leak Following Left Atrial Appendage Closure Using the LAmbre Device: A Comparative Study of CCTA and TEE. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70736

Vancouver

Shi G, Gu J, Duan Z, Wang B, Xie M, Zhang Z, et al. Anatomical and Imaging Predictors of Peri‐Device Leak Following Left Atrial Appendage Closure Using the LAmbre Device: A Comparative Study of CCTA and TEE. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70736

BibTeX
@article{Shi2026,
  author = {Shi, Genling and Gu, Junyin and Duan, Zhiyong and Wang, Bin and Xie, Mengshi and Zhang, Zhenzhou and Dai, Xixi and Xu, Zhong and Yao, Weifeng and Liu, Yunfei and Shi, Hongyu},
  title = {Anatomical and Imaging Predictors of Peri‐Device Leak Following Left Atrial Appendage Closure Using the LAmbre Device: A Comparative Study of CCTA and TEE},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70736}
}
Kostenlos starten →