EUVIMEDEUVIMED entdecken
Crossref

Image‐Based Analysis of Correlation Between Valve Stent Deformation and Valve Function in Transcatheter Aortic Valve Replacement

Min Jin, Qing Zhou, Shuchun Li, Haitao Zhang, Dongjin Wang iD

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31421 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Min Jin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Nanjing Drum Tower Hospital, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing, Jian…. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Stents, Aortic Valve, Transcatheter Aortic Valve Replacement. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: This work was financially supported by Nanjing Medical Science and technology development Foundation (Grant numbers YKK23091), National Natural Science Foundat….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives Currently, there remains a paucity of research on the deformation and valve function of transcatheter heart valves (THV) in patients with aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR). This study aimed to thoroughly explore the correlation between THV deformation and postoperative hemodynamics in these patients.

Methods

In this study, we assessed 39 AR patients treated with the J‐Valve THV system during TAVR. We utilized postoperative cardiac‐enhanced computed tomography angiography (CTA) to examine the extent of stent deformation, correlating these measurements with concurrent echocardiographic data.

Results

Among patients with AR, the J‐Valve exhibited three distinct configurations: rectangular, trapezoidal, and inverted trapezoidal shapes. The rectangular configuration showed a trend toward a larger effective orifice area (EOA) compared to the trapezoidal and inverted trapezoidal configurations (rectangular: 2.20 ± 0.11 cm², trapezoidal: 1.88 ± 0.08 cm², inverted trapezoidal: 2.04 ± 0.08 cm²; p = 0.068). Stratified analysis of the degree of inclined commissural posts indicated that THVs with all three commissural angles < 5° exhibited the highest standard EOA (sEOA). An increase in the number and degree of inclined commissural posts correlated with a decrease in sEOA. Furthermore, a higher EOA was observed when the expansion in the mid and transition level exceeded 80%.

Conclusions

During the TAVR procedure, ensuring sufficient expansion in the mid and transition level of the stent, maintaining the stent in a rectangular configuration, and avoiding tilting of the commissural posts contribute to achieving favorable postoperative hemodynamics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisStentsAortic ValveTranscatheter Aortic Valve ReplacementAortic Valve InsufficiencyComputed Tomography AngiographyAortic Valve StenosisCardiac CatheterizationHeart Valve Prosthesis ImplantationHumansMaleFemaleProsthesis DesignHemodynamicsTreatment OutcomeAged, 80 and overAgedRetrospective StudiesPredictive Value of Tests

Stichwörter der Autor:innen

computed tomographygeometrystent frametranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Department of Cardiac Surgery, Nanjing Drum Tower Hospital, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing, Jiangsu, China.
  • Department of Cardiac Surgery, Nanjing Drum Tower Hospital, Nanjing, Jiangsu, China.
  • Department of Cardiac Surgery, Nanjing Drum Tower Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Graduate School of Peking Union Medical College, Nanjing, Jiangsu, China.

ORCID-Profile: Dongjin Wang

Förderung

  • This work was financially supported by Nanjing Medical Science and technology development Foundation (Grant numbers YKK23091), National Natural Science Foundat…

Zitieren

APA

Jin, M., Zhou, Q., Li, S., Zhang, H., & Wang, D. (2025). Image‐Based Analysis of Correlation Between Valve Stent Deformation and Valve Function in Transcatheter Aortic Valve Replacement. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31421

Vancouver

Jin M, Zhou Q, Li S, Zhang H, Wang D. Image‐Based Analysis of Correlation Between Valve Stent Deformation and Valve Function in Transcatheter Aortic Valve Replacement. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31421

BibTeX
@article{Jin2025,
  author = {Jin, Min and Zhou, Qing and Li, Shuchun and Zhang, Haitao and Wang, Dongjin},
  title = {Image‐Based Analysis of Correlation Between Valve Stent Deformation and Valve Function in Transcatheter Aortic Valve Replacement},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31421}
}
Kostenlos starten →