Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus

Yutaka Matsuhiro iD, Isamu Mizote, Daisuke Nakamura, Tomoharu Dohi iD, Koichi Maeda, Kazuo Shimamura, Ai Kawamura iD, Kizuku Yamashita, Shumpei Kosugi iD, Shota Okuno iD, Hiroki Sugae, Yasuharu Takeda and 1 more

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31415 ↗

At a glance

Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Yutaka Matsuhiro and 12 co-authors. Institution: Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan. Major MEDLINE topics: Heart Valve Prosthesis, Bioprosthesis, Aortic Valve, Aortic Valve Stenosis. Cited 4 times so far (Crossref); 25 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: The authors received no specific funding for this work..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The long‐term valve durability of supra‐annular self‐expanding valves (SEV) and intra‐annular balloon‐expandable valves (BEV) in patients with small aortic annuli remains unexplored.

Aims

This study aimed to determine the long‐term bioprosthetic valve durability with SEV versus BEV in patients with small aortic annuli.

Methods

This retrospective study included patients with severe aortic stenosis (AS) and an aortic annulus area of 430 mm 2 or less who underwent transcatheter aortic valve replacement using SEV and BEV between October 2009 and December 2022. Based on the Valve Academic Research Consortium's three definitions, the endpoints were hemodynamic structural valve deterioration (SVD) and bioprosthetic valve failure (BVF). Inverse probability of treatment weighting (IPTW) was used to compare between the two groups and adjust for baseline characteristics. The Fine‐Gray subdistribution hazard model accounted for the competing risk of death.

Results

In total, 565 patients (204 treated with SEV and 361 treated with BEV) were included. The median follow‐up duration was 3.6 years [2.0 years, 5.7 years], and the maximum was 12.3 years. Hemodynamic SVD and BVF were less frequently identified in the SEV group than in the BEV group (1.1% vs. 9.1% within 5 years, 0.7% vs. 8.1% within 5 years, respectively). On the IPTW adjusted Fine‐Gray subdistribution hazard model analysis, hemodynamic SVD was less frequent in SEV compared with BEV (Hazard Ratio [HR]: 0.16; 95% Confidence Interval [CI]: 0.04–0.56, p = 0.004). SEV was also associated with a lower BVF risk than BEV (HR: 0.25; 95% CI: 0.08–0.76, p = 0.015).

Conclusions

SEV appears to be more suitable for long‐term valve durability in patients with a small aortic annulus.

Subjects

MeSH terms (MEDLINE)

Heart Valve ProsthesisBioprosthesisAortic ValveAortic Valve StenosisTranscatheter Aortic Valve ReplacementBalloon ValvuloplastyProsthesis FailureHumansRetrospective StudiesMaleFemaleProsthesis DesignTime FactorsTreatment OutcomeAgedAged, 80 and overRisk FactorsHemodynamicsRisk AssessmentSeverity of Illness Index

Author keywords

bioprosthetic valve failuresmall aortic annulusstructural valve deteriorationtranscatheter aortic valve replacement

Authors and institutions

  • Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Osaka, Japan.
  • Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Osaka, Japan.

ORCID profiles: Yutaka Matsuhiro, Tomoharu Dohi, Ai Kawamura, Shumpei Kosugi, Shota Okuno

Funding

  • The authors received no specific funding for this work.

Cite

APA

Matsuhiro, Y., Mizote, I., Nakamura, D., Dohi, T., Maeda, K., Shimamura, K., Kawamura, A., Yamashita, K., Kosugi, S., Okuno, S., Sugae, H., Takeda, Y., & Sakata, Y. (2025). Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31415

Vancouver

Matsuhiro Y, Mizote I, Nakamura D, Dohi T, Maeda K, Shimamura K, et al. Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31415

BibTeX
@article{Matsuhiro2025,
  author = {Matsuhiro, Yutaka and Mizote, Isamu and Nakamura, Daisuke and Dohi, Tomoharu and Maeda, Koichi and Shimamura, Kazuo and Kawamura, Ai and Yamashita, Kizuku and Kosugi, Shumpei and Okuno, Shota and Sugae, Hiroki and Takeda, Yasuharu and Sakata, Yasushi},
  title = {Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31415}
}
Start for free →