Durability of Bioprosthetic and Mechanical Valves Implanted for Aortic Valve Replacement in Pediatric Patients
Circulation: Cardiovascular Interventions · 2026-07 · 19 (7)
DOI: 10.1161/circinterventions.125.015931 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Circulation: Cardiovascular Interventions, 2026-07. Verfasst von Rumi Yokota und 8 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Pediatrics, Lucile Packard Children's Hospital Heart Center Clinical and Translational Research Program (R.Y., T.P., R.P., D.B.M.E.), …. Hauptthemen laut MEDLINE: Bioprosthesis, Heart Valve Prosthesis, Aortic Valve, Heart Valve Prosthesis Implantation. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: There is limited published information on bioprosthetic aortic valve durability. The purpose of this study was to assess the durability of bioprosthetic valves used for aortic valve replacement (AVR) in pediatric patients. METHODS: We reviewed all surgical AVR procedures performed from May 2002 to July 2024 in patients ≤21 years of age using a mechanical valve or bioprosthesis. Long-term valve-related outcomes were assessed with propensity-score-adjusted analysis. RESULTS: During the study period, 180 AVR procedures were performed in pediatric patients (median age, 14.3 years) using a bioprosthetic valve (n=79) or mechanical prosthesis (n=101). Freedom from reintervention was significantly shorter in patients with a bioprosthetic valve (77% at 5 years, 29% at 10 years) than those with a mechanical valve (88% at 5 years, 82% at 10 years; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Departments of Pediatrics, Lucile Packard Children's Hospital Heart Center Clinical and Translational Research Program (R.Y., T.P., R.P., D.B.M.E.), Stanford University School of Medicine, CA.
- Department of Cardiothoracic Surgery (Y.Z., A.J., E.M., M.M., F.L.H., D.B.M.E.), Stanford University School of Medicine, CA.
ORCID-Profile: Elisabeth Martin, Michael Ma, Rajesh Punn, Doff B McElhinney
Zitieren
APA
Yokota, R., Zhang, Y., Jaggi, A., Perry, T., Martin, E., Ma, M., Punn, R., Hanley, F. L., & McElhinney, D. B. (2026). Durability of Bioprosthetic and Mechanical Valves Implanted for Aortic Valve Replacement in Pediatric Patients. Circulation: Cardiovascular Interventions, 19(7). https://doi.org/10.1161/circinterventions.125.015931
Vancouver
Yokota R, Zhang Y, Jaggi A, Perry T, Martin E, Ma M, et al. Durability of Bioprosthetic and Mechanical Valves Implanted for Aortic Valve Replacement in Pediatric Patients. Circulation: Cardiovascular Interventions. 2026;19(7). doi:10.1161/circinterventions.125.015931
BibTeX
@article{Yokota2026,
author = {Yokota, Rumi and Zhang, Yulin and Jaggi, Ayush and Perry, Tristan and Martin, Elisabeth and Ma, Michael and Punn, Rajesh and Hanley, Frank L and McElhinney, Doff B},
title = {Durability of Bioprosthetic and Mechanical Valves Implanted for Aortic Valve Replacement in Pediatric Patients},
journal = {Circulation: Cardiovascular Interventions},
year = {2026},
volume = {19},
number = {7},
doi = {10.1161/circinterventions.125.015931}
}
EUVIMED