Systematische Übersicht in Catheterization and Cardiovascular Interventions, 2025. Written by Sant Kumar and 11 co-authors. Institution: Department of Cardiology, Creighton University School of Medicine, Phoenix, Arizona, USA. Major MEDLINE topics: Coronary Artery Disease, Angioplasty, Balloon, Coronary, Cardiac Catheters, Percutaneous Coronary Intervention. Cited 2 times so far (Crossref); 36 references. Funded by: The authors received no specific funding for this work..
Abstract (original language)
Introduction
The super high‐pressure NC balloon (OPN NC; SIS Medical AG, Winterthur, Switzerland) is increasingly used in percutaneous coronary intervention (PCI). We performed a systematic review and meta‐analysis of its efficacy and safety.
Methods
A systematic review was conducted using PubMed and the Cochrane Library to identify studies using the OPN NC balloon in PCI. Procedural success, major adverse cardiac events (MACE), coronary perforation, and other complications were pooled using weighted means, confidence intervals (CI), and I ² statistics for heterogeneity assessment.
Results
Twenty‐nine studies (5 prospective including 2 randomized‐controlled trials, 12 retrospective, and 12 case reports) were included in the systematic review, of which 11 (3 prospective, 8 retrospective) were included in the meta‐analysis. Of the 1015 meta‐analysis patients, 50.7% presented with stable angina and 21.6% with an acute coronary syndrome. Mean lesion length was 22.8 ± 13.7 mm, the prevalence of moderate or severe calcification was 93.7%, and 40.4% of lesions were in‐stent. Procedural success was 95.1% (95% CI 89.3%−98.8% with significant heterogeneity: I ² = 84.9%). The incidence of periprocedural MACE was 1.9% (95% CI 1.1%−2.8%, I ² 86.9%), and the incidence of coronary perforation was 0.6% (95% CI 0.3%−1.5%, I ² 87.2%).
Conclusions
Use of the OPN NC balloon is associated with high success and acceptable complication rates. The heterogeneity of outcomes underscores the need for additional studies and standardized definitions.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Creighton University School of Medicine, Phoenix, Arizona, USA.
- Minneapolis Heart Institute and Minneapolis Heart Institute Foundation, Abbott Northwestern Hospital, Minneapolis, Minnesota, USA.
- Division of Cardiovascular Disease, Henry Ford Hospital, Detroit, Michigan, USA.
- Department of Cardiology, Chandler Regional Medical Center, Chandler, Arizona, USA.
- Department of Cardiology, The Carl and Edyth Lindner Center for Research and Education, Cincinnati, Ohio, USA.
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts, USA.
ORCID profiles: Sant Kumar, Yader Sandoval, Nachiket J Patel, Tim Henry, Gautam Kumar, Emmanouil S Brilakis
Funding
- The authors received no specific funding for this work.
Cite
APA
Kumar, S., Jalli, S., Sandoval, Y., Alaswad, K., Patel, N. J., Henry, T., Doshi, D., Pershad, A., Seto, A., Kumar, G., Burke, M. N., & Brilakis, E. S. (2025). Systematic Review and Meta‐Analysis of the Super High‐Pressure Balloon (SIS‐OPN) for Percutaneous Coronary Intervention. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31403
Vancouver
Kumar S, Jalli S, Sandoval Y, Alaswad K, Patel NJ, Henry T, et al. Systematic Review and Meta‐Analysis of the Super High‐Pressure Balloon (SIS‐OPN) for Percutaneous Coronary Intervention. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31403
BibTeX
@article{Kumar2025,
author = {Kumar, Sant and Jalli, Sandeep and Sandoval, Yader and Alaswad, Khaldoon and Patel, Nachiket J and Henry, Tim and Doshi, Darshan and Pershad, Ashish and Seto, Arnold and Kumar, Gautam and Burke, M Nicholas and Brilakis, Emmanouil S},
title = {Systematic Review and Meta‐Analysis of the Super High‐Pressure Balloon (SIS‐OPN) for Percutaneous Coronary Intervention},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31403}
}
EUVIMED