EUVIMEDObjevte EUVIMED
Vergleichsstudie

Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users

Adil Salihu iD, Jade Zulauff, Mehdi Ali Gadiri, Anais Metzinger, Joanne Muller, Ioannis Skalidis, David Meier iD, Nathalie Noirclerc, Sarah Mauler-Wittwer, Aurelia Zimmerli, Olivier Muller, Stephane Fournier iD

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31384 ↗

At a glance

Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Adil Salihu and 11 co-authors. Institution: Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Major MEDLINE topics: Learning Curve, Coronary Angiography, Coronary Stenosis, Fractional Flow Reserve, Myocardial. 13 references. Funded by: The authors received no specific funding for this work..

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Quantitative flow ratio (QFR) and FFRangio are angiography‐based technologies used to perform functional assessment of coronary lesions from angiographic images, validated across multiple clinical studies. There is limited information on the learning curves associated with each technology.

Aims

This study aims to compare the learning curves of QFR and FFRangio in evaluating coronary stenoses, focusing on changes in analysis speed and accuracy compared to invasive measurements.

Methods

A team of five blinded investigators, including two nurses, one medical student, and one physician in training, underwent identical standardized training on both technologies. The time taken for each analysis and the computed FFR values were documented and compared against the invasive gold standard.

Results

A total of 270 lesions (54 coronary lesions in 44 patients) were retrospectively analyzed. The median invasive FFR value was 0.88 [IQR 0.5, 0.9]. The median time for analysis with QFR and FFRangio was 245 [IQR 62, 319] and 252 [IQR 82, 315] s, respectively ( p = 0.171). Both QFR and FFRangio demonstrated a significant reduction in the time required for analysis as experience increased ( p < 0.01). Regarding accuracy, the median difference with invasive FFR for QFR and FFRangio was 0.06 [IQR: 0, 0.12] and 0.06 [IQR: 0, 0.12], respectively ( p = 0.620). Both technologies reached a performance plateau early on, exhibiting comparable results throughout the study.

Conclusion

Initial training in QFR and FFRangio enables quick attainment of maximal performance, but further practice primarily enhances analysis speed while maintaining accuracy, for both software.

Subjects

MeSH terms (MEDLINE)

Learning CurveCoronary AngiographyCoronary StenosisFractional Flow Reserve, MyocardialSoftwareCardiac CatheterizationRadiographic Image Interpretation, Computer-AssistedCoronary Artery DiseaseCoronary VesselsHumansMaleRetrospective StudiesReproducibility of ResultsFemalePredictive Value of TestsMiddle AgedTime FactorsAgedClinical CompetenceObserver VariationSeverity of Illness Index

Author keywords

FFRangioQFRangiographic based FFRlearning curves

Authors and institutions

  • Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • MicroBioRobotic Systems Laboratory, Institute of Mechanical Engineering, EPFL, Lausanne, Switzerland.

ORCID profiles: Adil Salihu, David Meier, Stephane Fournier

Funding

  • The authors received no specific funding for this work.

Cite

APA

Salihu, A., Zulauff, J., Gadiri, M. A., Metzinger, A., Muller, J., Skalidis, I., Meier, D., Noirclerc, N., Mauler-Wittwer, S., Zimmerli, A., Muller, O., & Fournier, S. (2025). Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31384

Vancouver

Salihu A, Zulauff J, Gadiri MA, Metzinger A, Muller J, Skalidis I, et al. Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31384

BibTeX
@article{Salihu2025,
  author = {Salihu, Adil and Zulauff, Jade and Gadiri, Mehdi Ali and Metzinger, Anais and Muller, Joanne and Skalidis, Ioannis and Meier, David and Noirclerc, Nathalie and Mauler-Wittwer, Sarah and Zimmerli, Aurelia and Muller, Olivier and Fournier, Stephane},
  title = {Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31384}
}
Start for free →