Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31384 ↗At a glance
Vergleichsstudie in Catheterization and Cardiovascular Interventions, 2025. Written by Adil Salihu and 11 co-authors. Institution: Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Major MEDLINE topics: Learning Curve, Coronary Angiography, Coronary Stenosis, Fractional Flow Reserve, Myocardial. 13 references. Funded by: The authors received no specific funding for this work..
Abstract (original language)
Background
Quantitative flow ratio (QFR) and FFRangio are angiography‐based technologies used to perform functional assessment of coronary lesions from angiographic images, validated across multiple clinical studies. There is limited information on the learning curves associated with each technology.
Aims
This study aims to compare the learning curves of QFR and FFRangio in evaluating coronary stenoses, focusing on changes in analysis speed and accuracy compared to invasive measurements.
Methods
A team of five blinded investigators, including two nurses, one medical student, and one physician in training, underwent identical standardized training on both technologies. The time taken for each analysis and the computed FFR values were documented and compared against the invasive gold standard.
Results
A total of 270 lesions (54 coronary lesions in 44 patients) were retrospectively analyzed. The median invasive FFR value was 0.88 [IQR 0.5, 0.9]. The median time for analysis with QFR and FFRangio was 245 [IQR 62, 319] and 252 [IQR 82, 315] s, respectively ( p = 0.171). Both QFR and FFRangio demonstrated a significant reduction in the time required for analysis as experience increased ( p < 0.01). Regarding accuracy, the median difference with invasive FFR for QFR and FFRangio was 0.06 [IQR: 0, 0.12] and 0.06 [IQR: 0, 0.12], respectively ( p = 0.620). Both technologies reached a performance plateau early on, exhibiting comparable results throughout the study.
Conclusion
Initial training in QFR and FFRangio enables quick attainment of maximal performance, but further practice primarily enhances analysis speed while maintaining accuracy, for both software.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- MicroBioRobotic Systems Laboratory, Institute of Mechanical Engineering, EPFL, Lausanne, Switzerland.
ORCID profiles: Adil Salihu, David Meier, Stephane Fournier
Funding
- The authors received no specific funding for this work.
Cite
APA
Salihu, A., Zulauff, J., Gadiri, M. A., Metzinger, A., Muller, J., Skalidis, I., Meier, D., Noirclerc, N., Mauler-Wittwer, S., Zimmerli, A., Muller, O., & Fournier, S. (2025). Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31384
Vancouver
Salihu A, Zulauff J, Gadiri MA, Metzinger A, Muller J, Skalidis I, et al. Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31384
BibTeX
@article{Salihu2025,
author = {Salihu, Adil and Zulauff, Jade and Gadiri, Mehdi Ali and Metzinger, Anais and Muller, Joanne and Skalidis, Ioannis and Meier, David and Noirclerc, Nathalie and Mauler-Wittwer, Sarah and Zimmerli, Aurelia and Muller, Olivier and Fournier, Stephane},
title = {Head‐to‐Head Comparison of Learning Curves Between QFR and FFRangio Software Users},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31384}
}
EUVIMED