EUVIMEDScopri EUVIMED
Systematische ÜbersichtMetaanalyse

The Clinical Impact of Mitral Gradient Post Transcatheter Edge‐To‐Edge Repair: A Systematic Review and Meta‐Analysis

Mohamad S Alabdaljabar, Alyaman Almiro iD, Jibran Khan, Dana J Gerberi, M Hassan Murad, Jeremy J Thaden, Charanjit S Rihal, Mackram F Eleid iD

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31321 ↗

At a glance

Systematische Übersicht in Catheterization and Cardiovascular Interventions, 2025. Written by Mohamad S Alabdaljabar and 7 co-authors. Institution: Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota, USA. Major MEDLINE topics: Mitral Valve Insufficiency, Mitral Valve, Cardiac Catheterization, Heart Valve Prosthesis Implantation. Cited 3 times so far (Crossref); 33 references. Funded by: The authors received no specific funding for this work..

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Mitral transcatheter edge‐to‐edge repair (TEER) is a minimally invasive therapy for severe mitral regurgitation (MR) in patients with high surgical risk. TEER results in a tissue bridge that decreases mitral valve area, potentially leading to elevated mean gradient. The clinical impact of elevated gradient on outcomes is unclear.

Methods

This systematic review and meta‐analysis was based on a comprehensive search of five databases. We included studies that evaluated post mitral TEER gradient on one of the following outcomes: all‐cause mortality, combined endpoints, symptoms, hospitalizations, and mitral valve re‐intervention. Meta‐analysis was conducted using the random‐effects model.

Results

Out of 6458 citations, 17 studies were included (2017−2024) reporting on 7748 patients. There was significant heterogeneity between studies related to the cutoff used to define elevated gradient, etiology of MR, and outcomes. Elevated mitral gradient post TEER (4, 4.5, 5 mmHg) was associated with worse combined endpoint (HR = 1.35, 95% CI 1.07−1.71; I 2 64%), but not all‐cause mortality (HR = 1.25, 95% CI 0.97−1.59; I 2 45%) or risk of hospitalization. For the combined endpoint, this association was mainly significant in patients who had mitral gradient assessed using discharge echocardiogram (HR = 1.39, 95% CI 1.07−1.81; I 2 62%) for all patients and for those with degenerative MR.

Conclusion

Despite the heterogeneity between studies, the current analysis suggests that patients with elevated mitral gradient post TEER are at risk of worse clinical outcomes, particularly in patients who had mitral gradient assessed using discharge transthoracic echocardiogram.

Subjects

MeSH terms (MEDLINE)

Mitral Valve InsufficiencyMitral ValveCardiac CatheterizationHeart Valve Prosthesis ImplantationHemodynamicsHumansTreatment OutcomeRisk FactorsMaleFemaleSeverity of Illness IndexAgedTime FactorsRisk AssessmentRecovery of FunctionAged, 80 and overMiddle Aged

Author keywords

gradientmeta‐analysismitral TEERmitral regurgitationtranscatheter edge‐to‐edge repair

Authors and institutions

  • Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota, USA.
  • College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.
  • Mayo Clinic Libraries, Mayo Clinic, Rochester, Minnesota, USA.
  • Division of Public Health, Infectious Diseases, and Occupational Medicine, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

ORCID profiles: Alyaman Almiro, Mackram F Eleid

Funding

  • The authors received no specific funding for this work.

Cite

APA

Alabdaljabar, M. S., Almiro, A., Khan, J., Gerberi, D. J., Murad, M. H., Thaden, J. J., Rihal, C. S., & Eleid, M. F. (2025). The Clinical Impact of Mitral Gradient Post Transcatheter Edge‐To‐Edge Repair: A Systematic Review and Meta‐Analysis. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31321

Vancouver

Alabdaljabar MS, Almiro A, Khan J, Gerberi DJ, Murad MH, Thaden JJ, et al. The Clinical Impact of Mitral Gradient Post Transcatheter Edge‐To‐Edge Repair: A Systematic Review and Meta‐Analysis. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31321

BibTeX
@article{Alabdaljabar2025,
  author = {Alabdaljabar, Mohamad S and Almiro, Alyaman and Khan, Jibran and Gerberi, Dana J and Murad, M Hassan and Thaden, Jeremy J and Rihal, Charanjit S and Eleid, Mackram F},
  title = {The Clinical Impact of Mitral Gradient Post Transcatheter Edge‐To‐Edge Repair: A Systematic Review and Meta‐Analysis},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31321}
}
Start for free →