Transcatheter Mitral Valve Repair With the MitraClip Device for Prior Mitral Valve Repair Failure: Insights From the GIOTTO‐FAILS Study
Journal of the American Heart Association · 2024
DOI: 10.1161/jaha.123.033605 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of the American Heart Association, 2024. Verfasst von Arturo Giordano und 26 weiteren Autor:innen. Beteiligte Einrichtung: Unità Operativa di Interventistica Cardiovascolare Pineta Grande Hospital Castel Volturno Italy. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Cardiac Catheterization, Registries, Mitral Valve. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Minimally invasive mitral valve repair has a favorable risk–benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge‐to‐edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). Methods and Results We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long‐term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P =0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P =0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no ( P =0.558) patients. Clinical follow‐up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P >0.05). Propensity score–adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09–0.81]; P =0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P >0.05).
Conclusions
In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Unità Operativa di Interventistica Cardiovascolare Pineta Grande Hospital Castel Volturno Italy.
- Unità Operativa di Emodinamica Santa Lucia Hospital San Giuseppe Vesuviano Italy.
- Department of Medico-Surgical Sciences and Biotechnologies Sapienza University of Rome Latina Italy.
- Mediterranea Cardiocentro Naples Italy.
- Department of Cardiac Surgery Vita-Salute San Raffaele University, IRCCS San Raffaele Scientific Institute Milan Italy.
- Department of Cardiology IRCCS Policlinico San Donato, San Donato Milanese Milan Italy.
ORCID-Profile: Arturo Giordano, Filippo Finizio, Nicola Corcione, Michele Cimmino, Giuseppe Biondi-Zoccai, Paolo Denti, Antonio Popolo Rubbio, Anna Sonia Petronio, Salvatore Giordano, Francesco De Felice, Marianna Adamo, Matteo Montorfano, Giuseppe Tarantini, Francesco Giannini, Ida Monteforte, Emmanuel Villa, Angelo Squeri, Corrado Tamburino
Zitieren
APA
Giordano, A., Ferraro, P., Finizio, F., Corcione, N., Cimmino, M., Biondi-Zoccai, G., Denti, P., Rubbio, A. P., Petronio, A. S., Bartorelli, A. L., Mongiardo, A., Giordano, S., De Felice, F., Adamo, M., Montorfano, M., Baldi, C., Tarantini, G., Giannini, F., Ronco, F., …, & Bedogni, F. (2024). Transcatheter Mitral Valve Repair With the MitraClip Device for Prior Mitral Valve Repair Failure: Insights From the GIOTTO‐FAILS Study. Journal of the American Heart Association. https://doi.org/10.1161/jaha.123.033605
Vancouver
Giordano A, Ferraro P, Finizio F, Corcione N, Cimmino M, Biondi-Zoccai G, et al. Transcatheter Mitral Valve Repair With the MitraClip Device for Prior Mitral Valve Repair Failure: Insights From the GIOTTO‐FAILS Study. Journal of the American Heart Association. 2024. doi:10.1161/jaha.123.033605
BibTeX
@article{Giordano2024,
author = {Giordano, Arturo and Ferraro, Paolo and Finizio, Filippo and Corcione, Nicola and Cimmino, Michele and Biondi-Zoccai, Giuseppe and Denti, Paolo and Rubbio, Antonio Popolo and Petronio, Anna Sonia and Bartorelli, Antonio L and Mongiardo, Annalisa and Giordano, Salvatore and De Felice, Francesco and Adamo, Marianna and Montorfano, Matteo and Baldi, Cesare and Tarantini, Giuseppe and Giannini, Francesco and Ronco, Federico and Monteforte, Ida and Villa, Emmanuel and Ferrario, Maurizio and Fiocca, Luigi and Castriota, Fausto and Squeri, Angelo and Tamburino, Corrado and Bedogni, Francesco},
title = {Transcatheter Mitral Valve Repair With the MitraClip Device for Prior Mitral Valve Repair Failure: Insights From the GIOTTO‐FAILS Study},
journal = {Journal of the American Heart Association},
year = {2024},
doi = {10.1161/jaha.123.033605}
}
EUVIMED