Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Mark M P van den Dorpel und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Thoraxcenter, Cardiovascular Institute, Erasmus Medical Center, Rotterdam, The Netherlands. Hauptthemen laut MEDLINE: Mitral Valve, Heart Valve Prosthesis Implantation, Cardiac Catheterization, Heart Valve Prosthesis. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Transcatheter mitral valve replacement (TMVR) is emerging in the context of annular calcification (valve‐in‐MAC; ViMAC), failing surgical mitral annuloplasty (mitral‐valve‐in‐ring; MViR) and failing mitral bioprosthesis (mitral‐valve‐in‐valve; MViV). A notorious risk of TMVR is neo left ventricular outflow tract (neo‐LVOT) obstruction. Three‐dimensional computational models (3DCM) are derived from multi‐slice computed tomography (MSCT) and aim to predict neo‐LVOT area after TMVR. Little is known about the accuracy of these neo‐LVOT predictions for various mitral phenotypes.
Methods
Preprocedural 3DCMs were created for ViMAC, MViR and MViV cases. Throughout the cardiac cycle, neo‐LVOT dimensions were semi‐automatically calculated on the 3DCMs. We compared the predicted neo‐LVOT area on the preprocedural 3DCM with the actual neo‐LVOT as measured on the post‐procedural MSCT.
Results
Across 12 TMVR cases and examining 20%–70% of the cardiac phase, the mean difference between predicted and post‐TMVR neo‐LVOT area was −23 ± 28 mm 2 for MViR, −21 ± 34 mm 2 for MViV and −73 ± 61 mm 2 for ViMAC. The mean intra‐class correlation coefficient for absolute agreement between predicted and post‐procedural neo‐LVOT area (throughout the whole cardiac cycle) was 0.89 (95% CI 0.82–0.94, p < 0.001) for MViR, 0.81 (95% CI 0.62–0.89, p < 0.001) for MViV, and 0.41 (95% CI 0.12–0.58, p = 0.002 ) for ViMAC.
Conclusions
Three‐dimensional computational models accurately predict neo‐LVOT dimensions post TMVR in MViR and MViV but not in ViMAC. Further research should incorporate device host interactions and the effect of changing hemodynamics in these simulations to enhance accuracy in all mitral phenotypes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Thoraxcenter, Cardiovascular Institute, Erasmus Medical Center, Rotterdam, The Netherlands.
- Department of Cardiology, Amphia Ziekenhuis, Breda, The Netherlands.
- Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, The Netherlands.
ORCID-Profile: Mark M P van den Dorpel, Joost Daemen, Nicolas M Van Mieghem
Zitieren
APA
van den Dorpel, M. M. P., de Assis, L. U., van Niekerk, J., Nuis, R. J., Daemen, J., Ren, C. B., Hirsch, A., Kardys, I., van den Branden, B. J. L., Budde, R., & Van Mieghem, N. M. (2025). Accuracy of Three‐Dimensional Neo Left Ventricular Outflow Tract Simulations With Transcatheter Mitral Valve Replacement in Different Mitral Phenotypes. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31287
Vancouver
van den Dorpel MMP, de Assis LU, van Niekerk J, Nuis RJ, Daemen J, Ren CB, et al. Accuracy of Three‐Dimensional Neo Left Ventricular Outflow Tract Simulations With Transcatheter Mitral Valve Replacement in Different Mitral Phenotypes. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31287
BibTeX
@article{vandenDorpel2025,
author = {van den Dorpel, Mark M P and de Assis, Lucas Uchoa and van Niekerk, Jenna and Nuis, Rutger-Jan and Daemen, Joost and Ren, Claire Ben and Hirsch, Alexander and Kardys, Isabella and van den Branden, Ben J L and Budde, Ricardo and Van Mieghem, Nicolas M},
title = {Accuracy of Three‐Dimensional Neo Left Ventricular Outflow Tract Simulations With Transcatheter Mitral Valve Replacement in Different Mitral Phenotypes},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31287}
}
EUVIMED