CT‐derived simulations to predict outcomes in patients undergoing transcatheter aortic valve implantation with an ACURATE Neo2 valve the PRECISE‐TAVI cohort B trial
Catheterization and Cardiovascular Interventions · 2024
DOI: 10.1002/ccd.31194 ↗At a glance
Multizentrische Studie in Catheterization and Cardiovascular Interventions, 2024. Written by Thijmen W Hokken and 9 co-authors. Institution: Department of Cardiology, Cardiovascular Institute, Thoraxcenter, Erasmus University Medical Center, Rotterdam, The Netherlands. Major MEDLINE topics: Aortic Valve, Heart Valve Prosthesis, Predictive Value of Tests, Prosthesis Design. 16 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: PRECISE-TAVI cohort B is part of a project that has received funding from the European Union's Horizon 2020 research and innovation program.
Abstract (original language)
Background
Paravalvular leakage (PVL) and conduction disorders that require permanent pacemaker implantation (PPI) remain clinically relevant challenges after transcatheter aortic valve implantation (TAVI). Computed tomography‐based simulations may predict the risk of significant PVL and PPI.
Aims
To evaluate the feasibility and accuracy of preprocedural computer simulation with FEops HEARTguide™ to predict >trace PVL and PPI after TAVI with the self‐expanding supra‐annular ACURATE Neo2 transcatheter heart valve.
Methods
Prospective multicenter observational study that included consecutive patients undergoing TAVI with an ACURATE Neo2 valve. Computer simulations were performed before the TAVI procedure as part of the preprocedural planning. Follow‐up period for PPI and PVL was 30 days.
Results
Sixty‐five patients were included (median age 81 years (25th−75th percentile 77–84.5)). New left bundle branch block occurred in five patients (7.7%) and PPI in two patients (3%). Contact pressure index (CPI) was similar for patients with vs without new conduction disorders. Patients with PPI had numerically higher CPI than those without PPI (median CPI 20.0% (25th−75th percentile 15.0–25.0) vs. 13.0% (25th−75th percentile 5.5–18), p = 0.27). More than trace PVL occurred in 30%. Median PVL was significantly lower in patients with none‐trace PVL (3.2 mL/s [25th−75th percentile 2.2–5.0]), compared to mild PVL (5.2 mL/s [25th−75th percentile 3.2–10.3]) and moderate PVL (12.6 mL/s [25th−75th percentile 3.9–21.3])( p = 0.036). A simulated PVL‐cutoff of 9.65 mL/s identified patients with >trace PVL (AUC 0.70 (95% CI 0.55–0.85), sensitivity 42%, specificity 95%).
Conclusion
In our study FEops HEARTguide™ simulations identified patients at risk for >trace PVL with ACURATE Neo2 TAVI but not for PPI.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Cardiovascular Institute, Thoraxcenter, Erasmus University Medical Center, Rotterdam, The Netherlands.
- The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
- Department of Cardiac Surgery, IRCCS San Raffaele Scientific Institute, Milan, Italy.
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
ORCID profiles: Thijmen W Hokken, Philippe Nuyens, Joost Daemen, Nicola Buzzatti, Ole de Backer, Nicolas M Van Mieghem
Funding
- PRECISE-TAVI cohort B is part of a project that has received funding from the European Union's Horizon 2020 research and innovation program
Cite
APA
Hokken, T. W., Nuyens, P., Ruffo, C., Nuis, R. J., Daemen, J., Kardys, I., Budde, R., Buzzatti, N., de Backer, O., & Van Mieghem, N. M. (2024). CT‐derived simulations to predict outcomes in patients undergoing transcatheter aortic valve implantation with an ACURATE Neo2 valve the PRECISE‐TAVI cohort B trial. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31194
Vancouver
Hokken TW, Nuyens P, Ruffo C, Nuis RJ, Daemen J, Kardys I, et al. CT‐derived simulations to predict outcomes in patients undergoing transcatheter aortic valve implantation with an ACURATE Neo2 valve the PRECISE‐TAVI cohort B trial. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31194
BibTeX
@article{Hokken2024,
author = {Hokken, Thijmen W and Nuyens, Philippe and Ruffo, Claudio and Nuis, Rutger-Jan and Daemen, Joost and Kardys, Isabella and Budde, Ricardo and Buzzatti, Nicola and de Backer, Ole and Van Mieghem, Nicolas M},
title = {CT‐derived simulations to predict outcomes in patients undergoing transcatheter aortic valve implantation with an ACURATE Neo2 valve the PRECISE‐TAVI cohort B trial},
journal = {Catheterization and Cardiovascular Interventions},
year = {2024},
doi = {10.1002/ccd.31194}
}
EUVIMED