EUVIMEDOpdag EUVIMED
Fallbericht

Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report

Omar Abdel-Razek, Alessandro El Khoury, Daniel McGrail, Roger J Laham iD

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31177 ↗

At a glance

Fallbericht in Catheterization and Cardiovascular Interventions, 2024. Written by Omar Abdel-Razek and 3 co-authors. Institution: Division of Cardiology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA. Major MEDLINE topics: Aortic Valve Insufficiency, Heart Valve Prosthesis, Prosthesis Design, Aortic Valve. 13 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Transcutaneous aortic valve replacement (TAVR) has evolved from a complex procedure meant only for patients at prohibitive risk for surgery to a commonly performed procedure across a wide variety of clinical scenarios including the treatment of failed aortic valve bioprosthesis. Annuloplasty rings in the aortic position such as HAART 300 (Biostable Science and Engineering) have been introduced in the management of native aortic regurgitation. Percutaneous management of failed bioprosthesis rings in the aortic position has not been widely described. We present a case of a 69‐year‐old man with recurrent aortic regurgitation successfully treated with TAVR using a SAPIEN 3 valve within a HAART 300 ring.

Subjects

MeSH terms (MEDLINE)

Aortic Valve InsufficiencyHeart Valve ProsthesisProsthesis DesignAortic ValveProsthesis FailureHumansMaleAgedTreatment OutcomeHeart Valve Prosthesis ImplantationBioprosthesisTranscatheter Aortic Valve ReplacementRecurrence

Author keywords

aortic valve annuloplastyheart failure with reduced ejection fraction (HFrEF)transcutaneous aortic valve replacement (TAVR)transesophageal echocardiography (TEE)valve‐in‐valve (ViV) TAVR

Authors and institutions

  • Division of Cardiology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Anesthesia, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.

ORCID profiles: Roger J Laham

Cite

APA

Abdel-Razek, O., El Khoury, A., McGrail, D., & Laham, R. J. (2024). Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31177

Vancouver

Abdel-Razek O, El Khoury A, McGrail D, Laham RJ. Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31177

BibTeX
@article{AbdelRazek2024,
  author = {Abdel-Razek, Omar and El Khoury, Alessandro and McGrail, Daniel and Laham, Roger J},
  title = {Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31177}
}
Start for free →