EUVIMEDOpdag EUVIMED
Multizentrische StudieOpen access · CC BY-NC-ND 4.0

Feasibility of intentional bioprosthetic valve fracture in the tricuspid position

Jonathon A Hagel iD, C Huie Lin, Athar M Qureshi iD, Daniel Tanase iD, Andreas Eicken, Jeffrey D Zampi iD, Allison K Cabalka iD, Jason Anderson iD, Shabana Shahanavaz

Catheterization and Cardiovascular Interventions · 2024

DOI: 10.1002/ccd.31168 ↗

At a glance

Multizentrische Studie in Catheterization and Cardiovascular Interventions, 2024. Written by Jonathon A Hagel and 8 co-authors. Institution: The Heart Institute, Cincinnati Children's Hospital, University of Cincinnati, Cincinnati, Ohio, USA. Major MEDLINE topics: Heart Valve Prosthesis, Feasibility Studies, Heart Valve Prosthesis Implantation, Bioprosthesis. 19 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Transcatheter tricuspid valve‐in‐valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.

Aims

Evaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.

Methods

An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow‐up data were collected. Comparison was made to the pre‐ and post‐ViV replacement with fracture of the tricuspid valve frame conditions.

Results

Ten patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3–5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.

Conclusion

Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.

Subjects

MeSH terms (MEDLINE)

Heart Valve ProsthesisFeasibility StudiesHeart Valve Prosthesis ImplantationBioprosthesisProsthesis DesignRegistriesTricuspid ValveProsthesis FailureCardiac CatheterizationHumansFemaleMaleTreatment OutcomeAdultTime FactorsHemodynamicsYoung AdultRetrospective StudiesRecovery of FunctionUnited StatesAdolescentMiddle Aged

Author keywords

bioprosthetic valve fracture transcathetertricuspid valve replacementvalve replacementvalve‐in‐valve

Authors and institutions

  • The Heart Institute, Cincinnati Children's Hospital, University of Cincinnati, Cincinnati, Ohio, USA.
  • University of Michigan, C.S. Mott Children's Hospital, Ann Arbor, Michigan, USA.
  • Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas, USA.
  • Lillie Frank Abercrombie Section of Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas, USA.
  • Department of Pediatric Cardiology and Congenital Heart Defects, Deutsches Herzzentrum München, DHM, Munich, Germany.
  • Mayo Clinic College of Medicine, Department of Pediatrics, Division of Structural Heart Disease, Rochester, Now York, USA.

ORCID profiles: Jonathon A Hagel, Athar M Qureshi, Daniel Tanase, Jeffrey D Zampi, Allison K Cabalka, Jason Anderson

Cite

APA

Hagel, J. A., Lin, C. H., Qureshi, A. M., Tanase, D., Eicken, A., Zampi, J. D., Cabalka, A. K., Anderson, J., & Shahanavaz, S. (2024). Feasibility of intentional bioprosthetic valve fracture in the tricuspid position. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31168

Vancouver

Hagel JA, Lin CH, Qureshi AM, Tanase D, Eicken A, Zampi JD, et al. Feasibility of intentional bioprosthetic valve fracture in the tricuspid position. Catheterization and Cardiovascular Interventions. 2024. doi:10.1002/ccd.31168

BibTeX
@article{Hagel2024,
  author = {Hagel, Jonathon A and Lin, C Huie and Qureshi, Athar M and Tanase, Daniel and Eicken, Andreas and Zampi, Jeffrey D and Cabalka, Allison K and Anderson, Jason and Shahanavaz, Shabana},
  title = {Feasibility of intentional bioprosthetic valve fracture in the tricuspid position},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2024},
  doi = {10.1002/ccd.31168}
}
Start for free →