Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Kaitlyn Krebushevski und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric and Adolescent Medicine/Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Heart Valve Prosthesis Implantation, Pulmonary Valve, Heart Valve Prosthesis, Blood Vessel Prosthesis Implantation. Die Arbeit nennt 12 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Preparation of the right ventricular outflow tract (RVOT) using covered stent placement is a common preparatory step for transcatheter pulmonary valve replacement (TPVR) to reduce the risk of disruption associated with dilating calcified RVOT conduits.

Aim

We present a novel method employing a self‐expanding covered aortic endoprosthesis and discuss its advantages as an alternative strategy.

Methods

Patients with congenital heart disease undergoing RVOT conduit preparation with the GORE TAG Thoracic Branch Endoprosthesis Extender (W.L. Gore & Associates, Newark, DE) followed by TPVR, were prospectively enrolled in a dedicated database. To date, 14 patients have been included. Data on demographics, diagnoses, procedural details, hemodynamic parameters, and outcomes were analyzed.

Results

Fourteen patients (median age: 35 years [range: 18–79]; 57% female) successfully underwent endograft placement immediately before TPVR. Treated conduits included pulmonary homografts ( n = 8), surgical bioprostheses ( n = 2), Hancock conduit ( n = 1), Contegra conduit ( n = 1), native RVOT ( n = 1), and Melody valve within a surgical bioprosthesis ( n = 1). Most patients presented with mixed stenosis and regurgitation ( n = 9), with the remaining having stenosis ( n = 4) or regurgitation ( n = 1). Valves implanted post‐preparation included the Sapien S3 valve (Edwards Lifesciences, Irvine, CA) ( n = 10) and the Melody valve (Medtronic, Minneapolis, MN) ( n = 5). Significant reductions in RVOT systolic gradient were observed (median 34 mmHg pre‐procedure to 3 mmHg post‐procedure), along with marked conduit expansion (median diameter 13 mm pre‐procedure to 25.5 mm post‐procedure). No complications were reported.

Conclusions

This study highlights the feasibility of a self‐expanding aortic endoprosthesis for RVOT preparation before TPVR. Further comparative study is warranted. Procedural success was achieved in all cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve Prosthesis ImplantationPulmonary ValveHeart Valve ProsthesisBlood Vessel Prosthesis ImplantationCardiac CatheterizationBlood Vessel ProsthesisHeart Defects, CongenitalPulmonary Valve InsufficiencyStentsAortic ValveHumansFemaleMaleAdultAdolescentProsthesis DesignTreatment OutcomeYoung AdultMiddle AgedAgedHemodynamicsTime FactorsDatabases, FactualProspective StudiesBioprosthesisFeasibility Studies

Stichwörter der Autor:innen

aortic endograftaortic endoprosthesispre‐stentright ventricular outflow tractright ventricular outflow tract conduitstenttranscatheter pulmonary valve replacement

Autor:innen und Institutionen

  • Department of Pediatric and Adolescent Medicine/Division of Pediatric Cardiology, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Cardiovascular Medicine/Division of Structural Heart Diseases, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Cardiovascular Medicine, Mayo Clinic, Jacksonville, Florida, USA.

ORCID-Profile: Kaitlyn Krebushevski, Allison K Cabalka, Peter M Pollak, Liwei Yu, Jason H Anderson

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Krebushevski, K., Cabalka, A. K., Pollak, P. M., Yu, L., & Anderson, J. H. (2025). Self‐Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70039

Vancouver

Krebushevski K, Cabalka AK, Pollak PM, Yu L, Anderson JH. Self‐Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70039

BibTeX
@article{Krebushevski2025,
  author = {Krebushevski, Kaitlyn and Cabalka, Allison K and Pollak, Peter M and Yu, Liwei and Anderson, Jason H},
  title = {Self‐Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70039}
}
Kostenlos starten →