EUVIMEDEUVIMED entdecken
Crossref

Quality‐by‐Design–Driven Development and Validation of a Sensitive HPLC Method for Trace‐Level Determination of Nitrosamine Impurity in a Muscle Relaxant Drug Formulation

Vinod Kumar Manglige iD, Syam Sundhar Sai Kumar Boppana iD, Kiran Kumar Chagarlamudi iD, Venkata Siva Suryanarayana Gurram iD, Rajesh Damarapurapu iD, Sumanth Mullangi iD

Biomedical Chromatography · 2026-07 · 40 (7)

DOI: 10.1002/bmc.70474 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, online erschienen am 14.05.2026. Verfasst von Vinod Kumar Manglige und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University College of Sciences, Acharya Nagarjuna University, Nagarjuna Nagar, Andhra Pradesh, India. Hauptthemen laut MEDLINE: Drug Contamination, Nitrosamines. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

N ‐Nitroso impurities are very hazardous genotoxic carcinogens that can occur as by‐products or breakdown products in pharmaceutical compounds. In this study, a sensitive and quality‐by‐design–based high‐performance liquid chromatography method approach was developed and validated for the trace‐level determination of N ‐nitroso tizanidine in pharmaceutical formulations. Chromatographic separation was achieved using an XSelect HSS T3 column (100Å, 150 × 4.6 mm, 3.5 μm) and an isocratic mobile phase made up of 0.1% formic acid buffer and methanol (50:50 v/v) at a flow rate of 0.6 mL/min to separate the samples. The detection wavelength was set at 230 nm. The temperature of the column and sample was kept at 50°C and 10°C, respectively. A Box Behnken design was employed to evaluate the effects of critical method parameters, flow rate, column temperature, and methanol concentration on critical quality attributes, including retention time, tailing factor, and theoretical plate count. Quadratic models demonstrated good statistical significance with high correlation coefficients and nonsignificant lack‐of‐fit ( p > 0.05). The method was validated in accordance with ICHQ2 (R2) guidelines and exhibited excellent specificity, linearity, precision, accuracy, robustness, and sensitivity. The developed QbD–based method is suitable for routine quality control and regulatory monitoring of N‐NTIZ in both active pharmaceutical ingredients and finished dosage forms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drug ContaminationNitrosaminesChromatography, High Pressure LiquidReproducibility of ResultsLinear ModelsLimit of DetectionSensitivity and Specificity

Stichwörter der Autor:innen

N‐nitrosohigh‐performance liquid chromatographyquality‐by‐design approachtizanidine

Substanzen

Nitrosamines

Autor:innen und Institutionen

  • Department of Chemistry, University College of Sciences, Acharya Nagarjuna University, Nagarjuna Nagar, Andhra Pradesh, India.
  • Department of Chemistry, Vignan's Foundation for Science Technology & Research, Guntur, Andhra Pradesh, India.
  • Department of Chemistry, Koneru Lakshmaiah Education Foundation, Guntur (District), Andhra Pradesh, India.

ORCID-Profile: Vinod Kumar Manglige, Syam Sundhar Sai Kumar Boppana, Kiran Kumar Chagarlamudi, Venkata Siva Suryanarayana Gurram, Rajesh Damarapurapu, Sumanth Mullangi

Zitieren

APA

Manglige, V. K., Boppana, S. S. S. K., Chagarlamudi, K. K., Gurram, V. S. S., Damarapurapu, R., & Mullangi, S. (2026). Quality‐by‐Design–Driven Development and Validation of a Sensitive HPLC Method for Trace‐Level Determination of Nitrosamine Impurity in a Muscle Relaxant Drug Formulation. Biomedical Chromatography, 40(7). https://doi.org/10.1002/bmc.70474

Vancouver

Manglige VK, Boppana SSSK, Chagarlamudi KK, Gurram VSS, Damarapurapu R, Mullangi S. Quality‐by‐Design–Driven Development and Validation of a Sensitive HPLC Method for Trace‐Level Determination of Nitrosamine Impurity in a Muscle Relaxant Drug Formulation. Biomedical Chromatography. 2026;40(7). doi:10.1002/bmc.70474

BibTeX
@article{Manglige2026,
  author = {Manglige, Vinod Kumar and Boppana, Syam Sundhar Sai Kumar and Chagarlamudi, Kiran Kumar and Gurram, Venkata Siva Suryanarayana and Damarapurapu, Rajesh and Mullangi, Sumanth},
  title = {Quality‐by‐Design–Driven Development and Validation of a Sensitive HPLC Method for Trace‐Level Determination of Nitrosamine Impurity in a Muscle Relaxant Drug Formulation},
  journal = {Biomedical Chromatography},
  year = {2026},
  volume = {40},
  number = {7},
  doi = {10.1002/bmc.70474}
}
Kostenlos starten →