Multiple Reaction Monitoring LC‐MS/MS Quantification of N‐Nitrosamine Drug Substance Related Impurities of Clonidine in Drug Substance and in Tablet Dosage Form
Biomedical Chromatography · 2025
DOI: 10.1002/bmc.70123 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Bhaskar Vallamkonda und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Sciences, School of Applied Sciences and Humanities, Vignan's Foundation for Science, Technology & Research, Guntur, And…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Clonidine, Drug Contamination, Nitrosamines. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
N‐nitrosamine drug substance related impurities (NDSRIs) present recent concerns for manufacturers of both drug substances and products. The regulatory authorities prioritize understanding the chemical properties, potential formation, and control methods of these impurities due to their adverse effects. Clonidine is a medication for hypertension and attention deficit hyperactivity disorder, characterized by a secondary amine in its structure and a propensity to generate NDSRIs. Its chemical structural evaluation reveals a possible risk for the formation of two separate NDSRIs, namely, N‐nitroso and N‐dinitroso clonidine. The carcinogenic/mutagenic category was established using carcinogenic potency categorization approach method, and the corresponding acceptable intake values were implemented. A liquid chromatography–tandem mass spectrometry method in a multiple reaction monitoring mode was established to quantify both impurities in its drug substance and tablet dosage. A Poroshell C18 column of 150 × 4.6 mm, and with particle size of 2.7 μm was employed at a temperature of 30°C. A gradient elution method opted with water and acetonitrile as the mobile phases, containing formic acid as a buffering agent. Method validation conducted as per regulatory standards and demonstrated superior specificity, linearity, accuracy, precision, and robustness. As a result, this method is regarded as suitable for its intended purpose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmaceutical Sciences, School of Applied Sciences and Humanities, Vignan's Foundation for Science, Technology & Research, Guntur, Andhra Pradesh, India.
- Department of Pharmaceutical Analysis, Vignan Institute of Pharmaceutical Technology, Visakhapatnam, Andhra Pradesh, India.
ORCID-Profile: Bhaskar Vallamkonda, Srinivasa Rao Yarguntla, Ranadheer Reddy Challa
Zitieren
APA
Vallamkonda, B., Yarguntla, S. R., & Challa, R. R. (2025). Multiple Reaction Monitoring LC‐MS/MS Quantification of N‐Nitrosamine Drug Substance Related Impurities of Clonidine in Drug Substance and in Tablet Dosage Form. Biomedical Chromatography. https://doi.org/10.1002/bmc.70123
Vancouver
Vallamkonda B, Yarguntla SR, Challa RR. Multiple Reaction Monitoring LC‐MS/MS Quantification of N‐Nitrosamine Drug Substance Related Impurities of Clonidine in Drug Substance and in Tablet Dosage Form. Biomedical Chromatography. 2025. doi:10.1002/bmc.70123
BibTeX
@article{Vallamkonda2025,
author = {Vallamkonda, Bhaskar and Yarguntla, Srinivasa Rao and Challa, Ranadheer Reddy},
title = {Multiple Reaction Monitoring LC‐MS/MS Quantification of N‐Nitrosamine Drug Substance Related Impurities of Clonidine in Drug Substance and in Tablet Dosage Form},
journal = {Biomedical Chromatography},
year = {2025},
doi = {10.1002/bmc.70123}
}
EUVIMED