Pharmacokinetic study of iptacopan and its two acyl glucuronide metabolites in monkey plasma by liquid chromatography combined with electrospray ionization tandem mass spectrometry

Jingchu Li, Shanshan Liu, Chenglin Jia, Jiacheng Li, Zhihui Zhang, Jian Chen, Yongbin Cao, Chao Ma iD

Biomedical Chromatography · 2024

DOI: 10.1002/bmc.6002 ↗

At a glance

Journal article in Biomedical Chromatography, 2024. Written by Jingchu Li and 7 co-authors. Institution: Shanghai TCM-integrated Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China. Major MEDLINE topics: Tandem Mass Spectrometry, Glucuronides, Spectrometry, Mass, Electrospray Ionization. Cited 1 times so far (Crossref); 13 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

In this study, a simple and sensitive liquid chromatography tandem mass spectrometric method was developed and validated for the determination of iptacopan and two acyl glucuronidation metabolites in monkey plasma. The plasma sample was precipitated with acetonitrile and then separated on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm) using 0.1% formic acid and 5 mM ammonium acetate in water and acetonitrile as the mobile phase. The mass spectrometry (MS) detection was performed in positive multiple reactions monitoring (MRM) mode with precursor‐to‐production transitions. The developed assay was validated over the range of 1–2000 ng/mL for three analytes with correlation coefficient ( r ) more than 0.99. The validation parameters including accuracy, precision, carryover effect, matrix effect, recovery, and stability were all within the acceptable limits. The validated method has been applied to investigate the pharmacokinetics of iptacopan and its two acyl glucuronidation metabolites in monkey plasma. After intravenous administration, iptacopan showed low clearance (2.75 mL/min/kg) in monkey plasma. After oral administration, the bioavailability was 55.43%. The exposure (AUC 0− t ) of direct acyl glucuronide (AG) of iptacopan accounts for 9.73% of the iptacopan plasma exposure. The AUC 0− t of AG of dealkylated metabolite of iptacopan was present at a lower level, accounting for 0.5% of the iptacopan plasma exposure.

Subjects

MeSH terms (MEDLINE)

Tandem Mass SpectrometryGlucuronidesSpectrometry, Mass, Electrospray IonizationAnimalsReproducibility of ResultsMaleLinear ModelsChromatography, LiquidLimit of DetectionSensitivity and SpecificityMacaca fascicularisBenzoatesIndolesPiperidines

Author keywords

acyl glucuronidebioavailabilityiptacopanpharmacokinetics

Substances

GlucuronidesiptacopanBenzoatesIndolesPiperidines

Authors and institutions

  • Shanghai TCM-integrated Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China.

ORCID profiles: Chao Ma

Cite

APA

Li, J., Liu, S., Jia, C., Li, J., Zhang, Z., Chen, J., Cao, Y., & Ma, C. (2024). Pharmacokinetic study of iptacopan and its two acyl glucuronide metabolites in monkey plasma by liquid chromatography combined with electrospray ionization tandem mass spectrometry. Biomedical Chromatography. https://doi.org/10.1002/bmc.6002

Vancouver

Li J, Liu S, Jia C, Li J, Zhang Z, Chen J, et al. Pharmacokinetic study of iptacopan and its two acyl glucuronide metabolites in monkey plasma by liquid chromatography combined with electrospray ionization tandem mass spectrometry. Biomedical Chromatography. 2024. doi:10.1002/bmc.6002

BibTeX
@article{Li2024,
  author = {Li, Jingchu and Liu, Shanshan and Jia, Chenglin and Li, Jiacheng and Zhang, Zhihui and Chen, Jian and Cao, Yongbin and Ma, Chao},
  title = {Pharmacokinetic study of iptacopan and its two acyl glucuronide metabolites in monkey plasma by liquid chromatography combined with electrospray ionization tandem mass spectrometry},
  journal = {Biomedical Chromatography},
  year = {2024},
  doi = {10.1002/bmc.6002}
}