EUVIMEDEUVIMED entdecken
Crossref

Pharmacokinetic Study of HRO761 in Rats by Liquid Chromatography Combined With Electrospray Ionization Tandem Mass Spectrometry

Jie Shen iD, Liye Ge, Guowei Jiang, Yongjun Meng, Weina Ma

Biomedical Chromatography · 2025

DOI: 10.1002/bmc.70033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Chromatography, 2025. Verfasst von Jie Shen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pharmacy Department, Jiading District Central Hospital Affiliated Shanghai University of Medicine & Health Sciences, Shanghai, China. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Spectrometry, Mass, Electrospray Ionization. Die Arbeit nennt 8 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple and sensitive liquid chromatography tandem mass spectrometry method was established and validated for determination of HRO761 in rat plasma. After prepared by protein precipitation with acetonitrile, HRO761 and internal standard were separated on a Waters BEH C18 column using acetonitrile containing 0.1% formic acid and 0.1% formic acid in water as mobile phase by gradient elution. The method showed excellent linearity over the range of 5–5000 ng/mL with acceptable intraday and interday precision, accuracy, matrix effect, and recovery. The stability assay indicated that HRO761 was stable during the sample acquisition, preparation, and storage. The method was applied to pharmacokinetic study of HRO761 in rats. The result suggested that after intravenous administration at dose of 1 mg/kg, HRO761 was quickly eliminated from the plasma with the elimination half‐life of 1.9 h. After oral administration at doses of 5, 10, and 20 mg/kg, HRO761 was quickly absorbed into plasma and reach the peak concentration (C max ) of 2598.1–9379.2 ng/mL at 1.0–4.0 h. The exposure increased proportionally with the dose. The oral bioavailability was 79.0%–99.1% over the range of 5–20 mg/kg. This study provides useful information for its further development in clinic.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometrySpectrometry, Mass, Electrospray IonizationAnimalsRatsMaleRats, Sprague-DawleyReproducibility of ResultsLinear ModelsChromatography, LiquidLimit of DetectionSensitivity and SpecificityAdministration, OralDrug Stability

Stichwörter der Autor:innen

HRO761LC–MS/MSbioavailabilitypharmacokinetic

Autor:innen und Institutionen

  • Pharmacy Department, Jiading District Central Hospital Affiliated Shanghai University of Medicine & Health Sciences, Shanghai, China.

ORCID-Profile: Jie Shen

Zitieren

APA

Shen, J., Ge, L., Jiang, G., Meng, Y., & Ma, W. (2025). Pharmacokinetic Study of HRO761 in Rats by Liquid Chromatography Combined With Electrospray Ionization Tandem Mass Spectrometry. Biomedical Chromatography. https://doi.org/10.1002/bmc.70033

Vancouver

Shen J, Ge L, Jiang G, Meng Y, Ma W. Pharmacokinetic Study of HRO761 in Rats by Liquid Chromatography Combined With Electrospray Ionization Tandem Mass Spectrometry. Biomedical Chromatography. 2025. doi:10.1002/bmc.70033

BibTeX
@article{Shen2025,
  author = {Shen, Jie and Ge, Liye and Jiang, Guowei and Meng, Yongjun and Ma, Weina},
  title = {Pharmacokinetic Study of HRO761 in Rats by Liquid Chromatography Combined With Electrospray Ionization Tandem Mass Spectrometry},
  journal = {Biomedical Chromatography},
  year = {2025},
  doi = {10.1002/bmc.70033}
}