EUVIMEDObjevte EUVIMED
Crossref

Development of generic metabolic Raman calibration models using solution titration in aqueous phase and data augmentation for in‐line cell culture analysis

Zhijun Zhang, Zhe Lang, Gong Chen, Hang Zhou, Weichang Zhou

Biotechnology and Bioengineering · 2024

DOI: 10.1002/bit.28717 ↗

At a glance

Journal article in Biotechnology and Bioengineering, 2024. Written by Zhijun Zhang and 4 co-authors. Institution: Cell Culture Process Development (CCPD), WuXi Biologics, Shanghai, China. Major MEDLINE topics: Spectrum Analysis, Raman, Glucose, Lactic Acid, Cell Culture Techniques. Cited 10 times so far (Crossref); 35 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

This study presents a novel approach for developing generic metabolic Raman calibration models for in‐line cell culture analysis using glucose and lactate stock solution titration in an aqueous phase and data augmentation techniques. First, a successful set‐up of the titration method was achieved by adding glucose or lactate solution at several different constant rates into the aqueous phase of a bench‐top bioreactor. Subsequently, the in‐line glucose and lactate concentration were calculated and interpolated based on the rate of glucose and lactate addition, enabling data augmentation and enhancing the robustness of the metabolic calibration model. Nine different combinations of spectra pretreatment, wavenumber range selection, and number of latent variables were evaluated and optimized using aqueous titration data as training set and a historical cell culture data set as validation and prediction set. Finally, Raman spectroscopy data collected from 11 historical cell culture batches (spanning four culture modes and scales ranging from 3 to 200 L) were utilized to predict the corresponding glucose and lactate values. The results demonstrated a high prediction accuracy, with an average root mean square errors of prediction of 0.65 g/L for glucose, and 0.48 g/L for lactate. This innovative method establishes a generic metabolic calibration model, and its applicability can be extended to other metabolites, reducing the cost of deploying real‐time cell culture monitoring using Raman spectroscopy in bioprocesses.

Subjects

MeSH terms (MEDLINE)

Spectrum Analysis, RamanGlucoseLactic AcidCell Culture TechniquesCalibrationBioreactorsModels, BiologicalCHO CellsCricetulusCulture MediaAnimals

Author keywords

Raman spectroscopydata augmentationin‐line monitoringmetabolic modelingtitration

Substances

GlucoseLactic AcidCulture Media

Authors and institutions

  • Cell Culture Process Development (CCPD), WuXi Biologics, Shanghai, China.
  • Global Biologics Development and Operations (GBDO), WuXi Biologics, Shanghai, China.

Cite

APA

Zhang, Z., Lang, Z., Chen, G., Zhou, H., & Zhou, W. (2024). Development of generic metabolic Raman calibration models using solution titration in aqueous phase and data augmentation for in‐line cell culture analysis. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.28717

Vancouver

Zhang Z, Lang Z, Chen G, Zhou H, Zhou W. Development of generic metabolic Raman calibration models using solution titration in aqueous phase and data augmentation for in‐line cell culture analysis. Biotechnology and Bioengineering. 2024. doi:10.1002/bit.28717

BibTeX
@article{Zhang2024,
  author = {Zhang, Zhijun and Lang, Zhe and Chen, Gong and Zhou, Hang and Zhou, Weichang},
  title = {Development of generic metabolic Raman calibration models using solution titration in aqueous phase and data augmentation for in‐line cell culture analysis},
  journal = {Biotechnology and Bioengineering},
  year = {2024},
  doi = {10.1002/bit.28717}
}
Start for free →