EUVIMEDOpdag EUVIMED
Crossref

Evaluation of a single‐use disk stack centrifuge for improved efficiency and sustainability at 1000 L GMP manufacturing scale

Joshua Walker iD, Yik Lam, Abdullah Loman, John P Smelko, Michael Rohr

Biotechnology and Bioengineering · 2023

DOI: 10.1002/bit.28519 ↗

At a glance

Journal article in Biotechnology and Bioengineering, 2023. Written by Joshua Walker and 4 co-authors. Institution: Biogen, Durham, North Carolina, USA. Major MEDLINE topics: Bioreactors, Cell Culture Techniques. Cited 4 times so far (Crossref); 11 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Direct depth filtration is an established technology for single‐use harvest operation. Advantages of direct depth filtration include familiarity with depth filtration in downstream processes and simplicity of the operation. Drawbacks include low capacity, large footprint, labor‐intensive set‐up, high water use, and high waste in the form of discarded filters. Single‐use centrifugation is emerging as an alternative to depth filtration for the single‐use harvest step. Within the single‐use centrifugation space, disc stack centrifugation represents the newest entrant. In this study, we evaluated the performance of the GEA kytero single‐use disc stack centrifuge to clarify two monoclonal antibody‐producing cell culture fluids. The separation performance of the GEA kytero centrifuge varied between the two cell culture fluids, with differences in centrate turbidity and centrate filterability measured. A comparison was then performed to determine resource savings, compared to direct two‐stage depth filtration, when using a GEA kytero centrifuge to harvest a 1000 L bioreactor. The analysis concluded that replacement of the first stage of depth filters with a GEA kytero centrifuge has the potential to decrease the required second stage depth filtration area by up to 80%. The decrease in depth filter area resulting from the use of the GEA kytero would result in a decrease in the harvest step footprint, a decrease in buffer volume required to prime and rinse depth filters, and a decrease in the volume of plastic waste. An economic comparison of the GEA kytero single‐use centrifuge against a direct depth filtration step found that for a 1000 L harvest step, the GEA kytero centrifuge may reduce costs by up to 20% compared with two‐stage direct depth filtration.

Subjects

MeSH terms (MEDLINE)

BioreactorsCell Culture TechniquesCricetinaeAnimalsCricetulusCHO CellsCentrifugationFiltration

Author keywords

novel harvest technologiessingle-use disk stack centrifugationsustainability

Authors and institutions

  • Biogen, Durham, North Carolina, USA.
  • GEA, Northvale, New Jersey, USA.

ORCID profiles: Joshua Walker

Cite

APA

Walker, J., Lam, Y., Loman, A., Smelko, J. P., & Rohr, M. (2023). Evaluation of a single‐use disk stack centrifuge for improved efficiency and sustainability at 1000 L GMP manufacturing scale. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.28519

Vancouver

Walker J, Lam Y, Loman A, Smelko JP, Rohr M. Evaluation of a single‐use disk stack centrifuge for improved efficiency and sustainability at 1000 L GMP manufacturing scale. Biotechnology and Bioengineering. 2023. doi:10.1002/bit.28519

BibTeX
@article{Walker2023,
  author = {Walker, Joshua and Lam, Yik and Loman, Abdullah and Smelko, John P and Rohr, Michael},
  title = {Evaluation of a single‐use disk stack centrifuge for improved efficiency and sustainability at 1000 L GMP manufacturing scale},
  journal = {Biotechnology and Bioengineering},
  year = {2023},
  doi = {10.1002/bit.28519}
}
Start for free →