Improved sieving coefficient in perfusion cell culture with reduced effective filtration length of hollow fibers

Jimmy Vu iD, J Alex Gadberry, Jon Coffman, Ken Lee

Biotechnology Progress · 2024

DOI: 10.1002/btpr.3472 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biotechnology Progress, 2024. Verfasst von Jimmy Vu und 3 weiteren Autor:innen. Beteiligte Einrichtung: BioProcess Technologies & Engineering, BioPharmaceuticals Development, R&D, AstraZeneca, Gaithersburg, Maryland, USA. Hauptthemen laut MEDLINE: Filtration, Bioreactors, Cell Culture Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: AstraZeneca.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The hollow fiber filter is the primary cell‐retention device used in high‐density perfusion cell culture and often used in an alternating tangential flow (ATF) configuration. The limited commercially available diaphragm pumps for ATF prevent utilization of vertical space when scaling beyond 500 L. Stacking hollow fiber filters coupled with viscous cell culture imposes vacuum pressure exceeding facility capabilities. Additionally, the longer filter assembly increases the hold‐up volume and exceeds the diaphragm pump's fluid exchange capacity. The conventional tangential flow filtration (TFF) configuration circumvents this issue by exchanging culture from the bioreactor and cell‐retention device in a unidirectional recirculation loop; however, the increased filter length when scaled up exacerbates the TFF's inherent issue with product retention from Starling flow. Stacking commercially available 20 cm TFF filters to make up the similar single‐module length TFF used for the platform 3 and 50 L perfusion process at 41.5 and 65 cm, respectively, attempts to reduce fouling caused by Starling flow. The permeate of a single‐module filter is partitioned into short independent segments through serially stacked filters, each harvested separately. By partitioning the permeate, the sieving coefficient increased for both 3 and 50 L scales. Reduction of Starling flow was confirmed with lower total hydraulic membrane resistance throughout the culture. This work demonstrates a method for increasing sieving coefficient and filter capacity by stacking TFF filters with independent permeate streams.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FiltrationBioreactorsCell Culture TechniquesAnimalsCHO CellsPerfusionCricetulusEquipment Design

Stichwörter der Autor:innen

cell retentionhollow fibersperfusion cell cultureproduct retentiontangential flow filtration

Autor:innen und Institutionen

  • BioProcess Technologies & Engineering, BioPharmaceuticals Development, R&D, AstraZeneca, Gaithersburg, Maryland, USA.

ORCID-Profile: Jimmy Vu

Förderung

  • AstraZeneca

Zitieren

APA

Vu, J., Gadberry, J. A., Coffman, J., & Lee, K. (2024). Improved sieving coefficient in perfusion cell culture with reduced effective filtration length of hollow fibers. Biotechnology Progress. https://doi.org/10.1002/btpr.3472

Vancouver

Vu J, Gadberry JA, Coffman J, Lee K. Improved sieving coefficient in perfusion cell culture with reduced effective filtration length of hollow fibers. Biotechnology Progress. 2024. doi:10.1002/btpr.3472

BibTeX
@article{Vu2024,
  author = {Vu, Jimmy and Gadberry, J Alex and Coffman, Jon and Lee, Ken},
  title = {Improved sieving coefficient in perfusion cell culture with reduced effective filtration length of hollow fibers},
  journal = {Biotechnology Progress},
  year = {2024},
  doi = {10.1002/btpr.3472}
}
Kostenlos starten →