Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine
Luminescence · 2024-02 · 39 (2)
DOI: 10.1002/bio.4687 ↗At a glance
Journal article in Luminescence, published online on 2024-02-08. Written by Yandan Wang and 6 co-authors. Institution: School of Forensic Medicine, Shanxi Medical University, Jinzhong, Shanxi, P. R. China. Major MEDLINE topics: Methamphetamine, Biosensing Techniques, Aptamers, Nucleotide, Graphite. Cited 15 times so far (Crossref); 48 references. Funded by: Natural Science Foundation of Shanxi Province, China, Natural Science Foundation for Young Scientists of Shanxi Province.
Abstract (original language)
The construction of a fluorescence aptamer sensor was achieved by employing the fundamental principle of fluorescence resonance energy transfer. By employing molecular modeling technologies to identify the binding site, the high‐affinity aptamer APT‐40nt was derived from the whole sequence and utilized on the graphene oxide (GO) fluorescent platform for the purpose of achieving a highly sensitive detection of methamphetamine (METH). The aptamer tagged with fluorescein (FAM) dye undergoes quenching in the presence of GO due to π‐stacking interaction. With the addition of the target, the aptamer that has been tagged was detached from the GO surface, forming a stable complex with METH. This process resulted in fluorescence restoration of the system, and the degree of fluorescence restoration was proportional to METH concentration in the linear range of 1–50 and 50–200 nM. Notably, under optimized conditions, the detection limit of this aptasensor was as low as 0.78 nM, which meets the detection limit requirements of METH detection in saliva and urine in some countries and regions. Moreover, other common illicit drugs and metabolites had minimizing interference with the determination. The established aptasensor, therefore, has been successfully applied to detect METH in saliva and urine samples and exhibited satisfactory recoveries (87%–111%). This aptasensor has the advantages of low detection limit, excellent selectivity, ease of operation, and low cost, providing a promising strategy for on‐site detection of METH in saliva and urine.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- School of Forensic Medicine, Shanxi Medical University, Jinzhong, Shanxi, P. R. China.
- Shanxi Key Laboratory of Forensic Medicine, Jinzhong, Shanxi, P. R. China.
- Key Laboratory of Forensic Toxicology of Ministry of Public Security, Jinzhong, Shanxi, P. R. China.
ORCID profiles: Weifen Niu
Funding
- Natural Science Foundation of Shanxi Province, China
- Natural Science Foundation for Young Scientists of Shanxi Province
Cite
APA
Wang, Y., Wang, Z., Tong, Y., Zhang, D., Yun, K., Yan, J., & Niu, W. (2024). Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine. Luminescence, 39(2). https://doi.org/10.1002/bio.4687
Vancouver
Wang Y, Wang Z, Tong Y, Zhang D, Yun K, Yan J, et al. Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine. Luminescence. 2024;39(2). doi:10.1002/bio.4687
BibTeX
@article{Wang2024,
author = {Wang, Yandan and Wang, Zheyu and Tong, Yishuo and Zhang, Dan and Yun, Keming and Yan, Jiangwei and Niu, Weifen},
title = {Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine},
journal = {Luminescence},
year = {2024},
volume = {39},
number = {2},
doi = {10.1002/bio.4687}
}
EUVIMED