Real-Time and Selective Detection of Pseudomonas aeruginosa in Beef Samples Using a g-C3N4-Doped Multimetallic Perovskite-Based Electrochemical Aptasensor
Biosensors · 23.09.2025 · 15 (10) · 634
DOI: 10.3390/bios15100634 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 23.09.2025. Verfasst von Sarah S Albalawi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, University of Jeddah, P.O. Box 80327, Jeddah 21589, Saudi Arabia. Hauptthemen laut MEDLINE: Pseudomonas aeruginosa, Biosensing Techniques, Red Meat. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Jeddah.
Abstract (Originalsprache)
The alarming rise in foodborne illnesses, particularly those associated with microbial contamination in meat products, presents a serious challenge to global food safety. Among these microbial threats, Pseudomonas aeruginosa (P. aeruginosa) poses a critical threat due to its biofilm-forming capability and prevalence in contaminated beef, highlighting its effective real-time detection. Herein, we report the fabrication of a novel electrochemical aptasensor based on multimetal perovskite (FeCoCuNiO) doped with urea-derived graphitic carbon nitride (g-C3N4), synthesized via a sol–gel combustion method. The FeCoCuNiO-g-C3N4 nanocomposite was then coated onto a graphitic pencil electrode and functionalized with a DNA-based aptamer specific towards P. aeruginosa. The resulting aptasensor exhibited a low detection limit of 3.03 CFU mL−1 with high selectivity and sensitivity, and was successfully applied to real-time detection of P. aeruginosa in food samples. To the best of our knowledge, this work presents the first FeCoCuNiO-g-C3N4-based aptasensor for bacterial detection, offering a promising platform for food safety assurance and public health protection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, College of Science, University of Jeddah, P.O. Box 80327, Jeddah 21589, Saudi Arabia.
- Institute of Chemical Sciences, Bahauddin Zakariya University (BZU), Multan 60800, Pakistan.
ORCID-Profile: Naeem Akhtar
Förderung
- University of Jeddah
Zitieren
APA
Albalawi, S. S., Akhtar, N., & El-Said, W. A. (2025). Real-Time and Selective Detection of Pseudomonas aeruginosa in Beef Samples Using a g-C3N4-Doped Multimetallic Perovskite-Based Electrochemical Aptasensor. Biosensors, 15(10), 634. https://doi.org/10.3390/bios15100634
Vancouver
Albalawi SS, Akhtar N, El-Said WA. Real-Time and Selective Detection of Pseudomonas aeruginosa in Beef Samples Using a g-C3N4-Doped Multimetallic Perovskite-Based Electrochemical Aptasensor. Biosensors. 2025;15(10):634. doi:10.3390/bios15100634
BibTeX
@article{Albalawi2025,
author = {Albalawi, Sarah S and Akhtar, Naeem and El-Said, Waleed A},
title = {Real-Time and Selective Detection of Pseudomonas aeruginosa in Beef Samples Using a g-C3N4-Doped Multimetallic Perovskite-Based Electrochemical Aptasensor},
journal = {Biosensors},
year = {2025},
volume = {15},
number = {10},
pages = {634},
doi = {10.3390/bios15100634}
}
EUVIMED