EUVIMEDEUVIMED entdecken
Crossref

Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine

Yandan Wang, Zheyu Wang, Yishuo Tong, Dan Zhang, Keming Yun, Jiangwei Yan, Weifen Niu iD

Luminescence · 2024-02 · 39 (2)

DOI: 10.1002/bio.4687 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Luminescence, online erschienen am 08.02.2024. Verfasst von Yandan Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Forensic Medicine, Shanxi Medical University, Jinzhong, Shanxi, P. R. China. Hauptthemen laut MEDLINE: Methamphetamine, Biosensing Techniques, Aptamers, Nucleotide, Graphite. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Natural Science Foundation of Shanxi Province, China, Natural Science Foundation for Young Scientists of Shanxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The construction of a fluorescence aptamer sensor was achieved by employing the fundamental principle of fluorescence resonance energy transfer. By employing molecular modeling technologies to identify the binding site, the high‐affinity aptamer APT‐40nt was derived from the whole sequence and utilized on the graphene oxide (GO) fluorescent platform for the purpose of achieving a highly sensitive detection of methamphetamine (METH). The aptamer tagged with fluorescein (FAM) dye undergoes quenching in the presence of GO due to π‐stacking interaction. With the addition of the target, the aptamer that has been tagged was detached from the GO surface, forming a stable complex with METH. This process resulted in fluorescence restoration of the system, and the degree of fluorescence restoration was proportional to METH concentration in the linear range of 1–50 and 50–200 nM. Notably, under optimized conditions, the detection limit of this aptasensor was as low as 0.78 nM, which meets the detection limit requirements of METH detection in saliva and urine in some countries and regions. Moreover, other common illicit drugs and metabolites had minimizing interference with the determination. The established aptasensor, therefore, has been successfully applied to detect METH in saliva and urine samples and exhibited satisfactory recoveries (87%–111%). This aptasensor has the advantages of low detection limit, excellent selectivity, ease of operation, and low cost, providing a promising strategy for on‐site detection of METH in saliva and urine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MethamphetamineBiosensing TechniquesAptamers, NucleotideGraphiteOxidesLimit of DetectionFluorescent Dyes

Stichwörter der Autor:innen

binding active sitefluorescent aptasensorgraphene oxide (GO)methamphetamine (METH)

Substanzen

OxidesMethamphetamineAptamers, NucleotideFluorescent DyesGraphite

Autor:innen und Institutionen

  • School of Forensic Medicine, Shanxi Medical University, Jinzhong, Shanxi, P. R. China.
  • Shanxi Key Laboratory of Forensic Medicine, Jinzhong, Shanxi, P. R. China.
  • Key Laboratory of Forensic Toxicology of Ministry of Public Security, Jinzhong, Shanxi, P. R. China.

ORCID-Profile: Weifen Niu

Förderung

  • Natural Science Foundation of Shanxi Province, China
  • Natural Science Foundation for Young Scientists of Shanxi Province

Zitieren

APA

Wang, Y., Wang, Z., Tong, Y., Zhang, D., Yun, K., Yan, J., & Niu, W. (2024). Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine. Luminescence, 39(2). https://doi.org/10.1002/bio.4687

Vancouver

Wang Y, Wang Z, Tong Y, Zhang D, Yun K, Yan J, et al. Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine. Luminescence. 2024;39(2). doi:10.1002/bio.4687

BibTeX
@article{Wang2024,
  author = {Wang, Yandan and Wang, Zheyu and Tong, Yishuo and Zhang, Dan and Yun, Keming and Yan, Jiangwei and Niu, Weifen},
  title = {Aptamer‐based fluorescent sensor for highly sensitive detection of methamphetamine},
  journal = {Luminescence},
  year = {2024},
  volume = {39},
  number = {2},
  doi = {10.1002/bio.4687}
}
Kostenlos starten →