EUVIMEDOpdag EUVIMED
Open access · CC BY-NC 4.0

Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz

Ninad Chitnis iD, Fariba Karimi iD, Sven Kühn, Arya Fallahi, Andreas Christ iD, Niels Kuster iD

Bioelectromagnetics · 2025-09 · 46 (6)

DOI: 10.1002/bem.70018 ↗

At a glance

Journal article in Bioelectromagnetics, published online on 2025-08-13. Written by Ninad Chitnis and 5 co-authors. Institution: Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland. Major MEDLINE topics: Electromagnetic Fields, Radiometry. Cited 3 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: This study was co-funded by the following funding sources:Innosuisse project 45998.1.The European Union's Horizon Europe Framework Program under Grant Agreemen….

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

In this study, a comprehensive approach for the experimental assessment of the absorbed power density (APD) is developed. The method includes several novel components: (i) a specialized probe, (ii) a composite phantom, (iii) a reconstruction technique, (iv) a calibration method, and (v) a validation process. The described solution has been developed for the frequency range from 24 to 30 GHz, but can be extended to all frequency bands between 10 and 45 GHz. A novel composite phantom emulates the reflection and transmission coefficients of human skin for propagating and evanescent modes, while its increased penetration depth, in comparison to dermis tissue, enables the measurement of the induced electromagnetic fields (EMFs) with a new miniaturized dosimetric broadband probe. The implementation has a wide dynamic range and sufficient spatial resolution to use it for type approval of mobile devices. Its probe is calibrated with low uncertainty in a novel, traceable setup. A set of reference antennas with known numerical target values for the APD has been compiled to validate the measurement system. The validation demonstrates that the deviation is within the expanded uncertainty of 1.6 dB for pAPD and 1.5 dB for psAPD.

Subjects

MeSH terms (MEDLINE)

Electromagnetic FieldsRadiometryHumansPhantoms, ImagingCalibrationSkinUncertainty

Author keywords

5G NR FR2APD assessment systemabsorbed power density (APD)dosimetric probedosimetryfield reconstructionmillimeter‐wavesphantom

Authors and institutions

  • Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.
  • Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.

ORCID profiles: Ninad Chitnis, Fariba Karimi, Andreas Christ, Niels Kuster

Funding

  • This study was co-funded by the following funding sources:Innosuisse project 45998.1.The European Union's Horizon Europe Framework Program under Grant Agreemen…

Cite

APA

Chitnis, N., Karimi, F., Kühn, S., Fallahi, A., Christ, A., & Kuster, N. (2025). Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz. Bioelectromagnetics, 46(6). https://doi.org/10.1002/bem.70018

Vancouver

Chitnis N, Karimi F, Kühn S, Fallahi A, Christ A, Kuster N. Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz. Bioelectromagnetics. 2025;46(6). doi:10.1002/bem.70018

BibTeX
@article{Chitnis2025,
  author = {Chitnis, Ninad and Karimi, Fariba and Kühn, Sven and Fallahi, Arya and Christ, Andreas and Kuster, Niels},
  title = {Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz},
  journal = {Bioelectromagnetics},
  year = {2025},
  volume = {46},
  number = {6},
  doi = {10.1002/bem.70018}
}
Start for free →