Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz
Bioelectromagnetics · 2025-09 · 46 (6)
DOI: 10.1002/bem.70018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioelectromagnetics, online erschienen am 13.08.2025. Verfasst von Ninad Chitnis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland. Hauptthemen laut MEDLINE: Electromagnetic Fields, Radiometry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: This study was co-funded by the following funding sources:Innosuisse project 45998.1.The European Union's Horizon Europe Framework Program under Grant Agreemen….
Abstract (Originalsprache)
In this study, a comprehensive approach for the experimental assessment of the absorbed power density (APD) is developed. The method includes several novel components: (i) a specialized probe, (ii) a composite phantom, (iii) a reconstruction technique, (iv) a calibration method, and (v) a validation process. The described solution has been developed for the frequency range from 24 to 30 GHz, but can be extended to all frequency bands between 10 and 45 GHz. A novel composite phantom emulates the reflection and transmission coefficients of human skin for propagating and evanescent modes, while its increased penetration depth, in comparison to dermis tissue, enables the measurement of the induced electromagnetic fields (EMFs) with a new miniaturized dosimetric broadband probe. The implementation has a wide dynamic range and sufficient spatial resolution to use it for type approval of mobile devices. Its probe is calibrated with low uncertainty in a novel, traceable setup. A set of reference antennas with known numerical target values for the APD has been compiled to validate the measurement system. The validation demonstrates that the deviation is within the expanded uncertainty of 1.6 dB for pAPD and 1.5 dB for psAPD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland.
- Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.
ORCID-Profile: Ninad Chitnis, Fariba Karimi, Andreas Christ, Niels Kuster
Förderung
- This study was co-funded by the following funding sources:Innosuisse project 45998.1.The European Union's Horizon Europe Framework Program under Grant Agreemen…
Zitieren
APA
Chitnis, N., Karimi, F., Kühn, S., Fallahi, A., Christ, A., & Kuster, N. (2025). Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz. Bioelectromagnetics, 46(6). https://doi.org/10.1002/bem.70018
Vancouver
Chitnis N, Karimi F, Kühn S, Fallahi A, Christ A, Kuster N. Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz. Bioelectromagnetics. 2025;46(6). doi:10.1002/bem.70018
BibTeX
@article{Chitnis2025,
author = {Chitnis, Ninad and Karimi, Fariba and Kühn, Sven and Fallahi, Arya and Christ, Andreas and Kuster, Niels},
title = {Traceable Assessment of the Absorbed Power Density of Body Mounted Devices at Frequencies Above 10 GHz},
journal = {Bioelectromagnetics},
year = {2025},
volume = {46},
number = {6},
doi = {10.1002/bem.70018}
}