EUVIMEDEUVIMED entdecken
Open Access

Brain‐implanted conductors amplify radiofrequency fields in rodents: Advantages and risks

Mihály Vöröslakos, Omid Yaghmazadeh, Leeor Alon, Daniel K Sodickson, György Buzsáki

Bioelectromagnetics · 2024

DOI: 10.1002/bem.22489 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioelectromagnetics, 2024. Verfasst von Mihály Vöröslakos und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neuroscience and Physiology, Neuroscience Institute, Langone Medical Center, New York University, New York, New York, USA. Hauptthemen laut MEDLINE: Rodentia, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NINDS NIH HHS, NCATS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past few decades, daily exposure to radiofrequency (RF) fields has been increasing due to the rapid development of wireless and medical imaging technologies. Under extreme circumstances, exposure to very strong RF energy can lead to heating of body tissue, even resulting in tissue injury. The presence of implanted devices, moreover, can amplify RF effects on surrounding tissue. Therefore, it is important to understand the interactions of RF fields with tissue in the presence of implants, in order to establish appropriate wireless safety protocols, and also to extend the benefits of medical imaging to increasing numbers of people with implanted medical devices. This study explored the neurological effects of RF exposure in rodents implanted with neuronal recording electrodes. We exposed freely moving and anesthetized rats and mice to 950 MHz RF energy while monitoring their brain activity, temperature, and behavior. We found that RF exposure could induce fast onset firing of single neurons without heat injury. In addition, brain implants enhanced the effect of RF stimulation resulting in reversible behavioral changes. Using an optical temperature measurement system, we found greater than tenfold increase in brain temperature in the vicinity of the implant. On the one hand, our results underline the importance of careful safety assessment for brain‐implanted devices, but on the other hand, we also show that metal implants may be used for neurostimulation if brain temperature can be kept within safe limits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RodentiaMagnetic Resonance ImagingHumansRatsMiceAnimalsBrainRadio WavesProstheses and ImplantsPhantoms, ImagingHot Temperature

Stichwörter der Autor:innen

brain implantsbrain stimulationimplant safetyradiofrequency stimulation

Autor:innen und Institutionen

  • Department of Neuroscience and Physiology, Neuroscience Institute, Langone Medical Center, New York University, New York, New York, USA.
  • Department of Radiology, Grossman School of Medicine, New York University, New York, New York, USA.
  • Department of Neurology, Grossman School of Medicine, New York University, New York, New York, USA.

Förderung

  • NIBIB NIH HHS
  • NINDS NIH HHS
  • NCATS NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Vöröslakos, M., Yaghmazadeh, O., Alon, L., Sodickson, D. K., & Buzsáki, G. (2024). Brain‐implanted conductors amplify radiofrequency fields in rodents: Advantages and risks. Bioelectromagnetics. https://doi.org/10.1002/bem.22489

Vancouver

Vöröslakos M, Yaghmazadeh O, Alon L, Sodickson DK, Buzsáki G. Brain‐implanted conductors amplify radiofrequency fields in rodents: Advantages and risks. Bioelectromagnetics. 2024. doi:10.1002/bem.22489

BibTeX
@article{Vrslakos2024,
  author = {Vöröslakos, Mihály and Yaghmazadeh, Omid and Alon, Leeor and Sodickson, Daniel K and Buzsáki, György},
  title = {Brain‐implanted conductors amplify radiofrequency fields in rodents: Advantages and risks},
  journal = {Bioelectromagnetics},
  year = {2024},
  doi = {10.1002/bem.22489}
}
Kostenlos starten →