Fachartikel in der Zeitschrift Biotechnology and Applied Biochemistry, 2026. Verfasst von Guiyin Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, China. Hauptthemen laut MEDLINE: Quantum Dots, Graphite, Aptamers, Nucleotide, Nitrogen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: National Nature Science Foundation of China, Guangxi Science and Technology Major Program, Special Projects in Key Areas of Ordinary Universities in Guangdong Province.
Abstract (Originalsprache)
In this paper, a fluorescent aptamer sensor based on magnetic ferroferric oxide@boron, nitrogen‐doped graphene quantum dots (Fe 3 O 4 @B,N‐GQDs) was developed to detect Golgi protein 73 (GP73). GP73 aptamer (GP73 Apt ) functioned with Fe 3 O 4 @B,N‐GQDs (Fe 3 O 4 @B,N‐GQDs‐GP73 Apt ) and was used as the fluorescent donor, while molybdenum disulfide (MoS 2 ) with a large surface served as the fluorescent acceptor. The fluorescence of Fe 3 O 4 @B,N‐GQDs‐GP73 Apt was quenched by MoS 2 based on the fluorescence resonance energy transfer (FRET) principle. However, in the presence of GP73, Fe 3 O 4 @B,N‐GQDs‐GP73 Apt could specifically bind to GP73, forming a Fe 3 O 4 @B,N‐GQDs‐GP73 Apt ‐GP73 complex. This binding event caused Fe 3 O 4 @B,N‐GQDs‐GP73 Apt to move away from the surface of MoS 2 , thus blocking the FRET process and recovering the fluorescence. Under optimal conditions, a linear relationship was established between the fluorescence recovery and the concentration of GP73 within the range of 10–1000 ng/mL ( R 2 = 0.9918), and the limit of detection was 7.37 ng/mL. Additionally, when the sensor was applied to test actual samples, the recovery rates were in the range of 98.80%–101.18%, and the relative standard deviations were between 0.29%–3.04%. These findings demonstrated the excellent detection performance of the proposed fluorescent aptamer sensor.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry, Guangdong University of Petrochemical Technology, Maoming, Guangdong, China.
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting T…
ORCID-Profile: Guiyin Li
Förderung
- National Nature Science Foundation of China
- Guangxi Science and Technology Major Program
- Special Projects in Key Areas of Ordinary Universities in Guangdong Province
- The Projects of Talents Recruitment of GDUPT
- National Natural Science Foundation of China
Zitieren
APA
Li, G., He, W., Yan, R., Su, X., Yu, T., Tan, X., & Huang, Y. (2026). A Fluorescent Aptamer Sensor for Detecting Golgi Protein 73 Based on Magnetic Ferroferric Oxide@Boron, Nitrogen‐Doped Graphene Quantum Dots. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.70006
Vancouver
Li G, He W, Yan R, Su X, Yu T, Tan X, et al. A Fluorescent Aptamer Sensor for Detecting Golgi Protein 73 Based on Magnetic Ferroferric Oxide@Boron, Nitrogen‐Doped Graphene Quantum Dots. Biotechnology and Applied Biochemistry. 2026. doi:10.1002/bab.70006
BibTeX
@article{Li2026,
author = {Li, Guiyin and He, Wei and Yan, Ruijie and Su, Xuanlong and Yu, Tingting and Tan, Xiaohong and Huang, Yong},
title = {A Fluorescent Aptamer Sensor for Detecting Golgi Protein 73 Based on Magnetic Ferroferric Oxide@Boron, Nitrogen‐Doped Graphene Quantum Dots},
journal = {Biotechnology and Applied Biochemistry},
year = {2026},
doi = {10.1002/bab.70006}
}
EUVIMED