A liquid crystal‐based sensor exploiting the aptamer‐mediated recognition at the aqueous/liquid crystal interface for sensitive detection of serotonin
Biotechnology and Applied Biochemistry · 2023
DOI: 10.1002/bab.2503 ↗At a glance
Journal article in Biotechnology and Applied Biochemistry, 2023. Written by Je-Jin Ryu and 1 co-authors. Institution: Department of Chemistry, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea. Major MEDLINE topics: Liquid Crystals, Biosensing Techniques. Cited 9 times so far (Crossref); 46 references. Funded by: Basic Science Research Program of the National Research Foundation of Korea (NRF), funded by the Ministry of Education, Gachon University research fund of 2022.
Abstract (original language)
We report here a liquid crystal (LC)‐based sensor for detecting serotonin (5‐HT); the proposed sensor uses target‐specific aptamer recognition at a cationic surfactant decorated‐aqueous/LC interface. Our detection strategy focuses on the orientational transition of LCs upon biological interactions at the interface. In this sensing system, the cationic surfactant hexadecyltrimethylammonium bromide (CTAB) forms a self‐assembled monolayer at the aqueous/LC interface and triggers the homeotropic orientation of LCs. After introducing the 5‐HT specific aptamer, an electrostatic attraction occurs between the cationic CTAB and anionic aptamer. This interaction destructs the surfactant monolayer at the interface, inducing reorganization of LC alignment from homeotropic to tilted conditions. In the increasing 5‐HT levels, specific binding between 5‐HT and the aptamer diminishes the interaction between the aptamer and CTAB, thereby maintaining the homeotropic alignment of LCs. The orientational transition of the LCs was observed under a polarized optical microscope. The developed biosensor has a linear detection range from 1 to 1000 nM and a detection limit of 1.68 nM. Moreover, the sensor was applied to a human urine sample and a detection limit of 2.25 nM was obtained. Overall, the designed LC‐based sensor is a sensitive, simple, cost effective, and selective platform for detecting 5‐HT in aqueous solutions.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Chemistry, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea.
ORCID profiles: Chang-Hyun Jang
Funding
- Basic Science Research Program of the National Research Foundation of Korea (NRF), funded by the Ministry of Education
- Gachon University research fund of 2022
Cite
APA
Ryu, J. J., & Jang, C. H. (2023). A liquid crystal‐based sensor exploiting the aptamer‐mediated recognition at the aqueous/liquid crystal interface for sensitive detection of serotonin. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.2503
Vancouver
Ryu JJ, Jang CH. A liquid crystal‐based sensor exploiting the aptamer‐mediated recognition at the aqueous/liquid crystal interface for sensitive detection of serotonin. Biotechnology and Applied Biochemistry. 2023. doi:10.1002/bab.2503
BibTeX
@article{Ryu2023,
author = {Ryu, Je-Jin and Jang, Chang-Hyun},
title = {A liquid crystal‐based sensor exploiting the aptamer‐mediated recognition at the aqueous/liquid crystal interface for sensitive detection of serotonin},
journal = {Biotechnology and Applied Biochemistry},
year = {2023},
doi = {10.1002/bab.2503}
}
EUVIMED