EUVIMEDEUVIMED entdecken
Crossref

Innovative approaches to suppress non-specific adsorption in molecularly imprinted polymers for sensing applications

Abdelhafid Karrat, Aziz Amine

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116053 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Abdelhafid Karrat und 1 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Process Engineering and Environment, Faculty of Sciences and Techniques, Hassan II University of Casablanca, B.P. 146 Mohammedia, Moroc…. Hauptthemen laut MEDLINE: Molecular Imprinting, Biosensing Techniques. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Université Hassan II Casablanca.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Molecularly imprinted polymers (MIPs) are synthetic antibodies developed to bind selectively with specific molecules. They function through a particular recognition process involving their cavities and functional groups. Nevertheless, functional groups located outside these cavities are the main cause of non-specific molecule binding, thus reducing the effectiveness of MIPs in sensing applications. This work focused on enhancing the selectivity and performance of MIPs through electrostatic modification with surfactants. The study investigates the use of two surfactants, namely sodium dodecyl sulfate (SDS) and cetyl trimethyl ammonium bromide (CTAB), to eliminate non-specific adsorption in MIPs. The binding isotherms of the target molecule sulfamethoxazole (SMX) on MIPs and non-imprinted polymers (NIPs) were analyzed, showing higher adsorption capacity of MIPs due to the specific cavities. The modification with SDS or CTAB effectively eliminated non-specific adsorption in MIPs. The kinetic adsorption behavior further demonstrated the efficacy of MIP+--SDS/CTAB in the selective adsorption of SMX. Calibration curves showcase the methodology's analytical capabilities, achieving low limit of detection for SMX 6 ng mL-1 using MIP +-SDS. The stability study confirmed that the developed MIP +/--SDS/CTAB remains stable even at high temperatures, demonstrating its suitability for on-site applications. The methodology was successfully applied to detect SMX in milk and water samples, achieving promising recoveries. Overall, the electrostatic modification of MIPs with surfactants emerges as a valuable strategy for enhancing selectivity and performance in target molecule recognition and detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Molecular ImprintingBiosensing TechniquesMolecularly Imprinted PolymersAdsorptionCetrimoniumSulfamethoxazoleSurface-Active Agents

Stichwörter der Autor:innen

Molecularly imprinted polymersNon-specific adsorptionSmartphone detectionSulfamethoxazoleSurfactant

Substanzen

Molecularly Imprinted PolymersCetrimoniumSulfamethoxazoleSurface-Active Agents

Autor:innen und Institutionen

  • Laboratory of Process Engineering and Environment, Faculty of Sciences and Techniques, Hassan II University of Casablanca, B.P. 146 Mohammedia, Morocco.
  • Laboratory of Process Engineering and Environment, Faculty of Sciences and Techniques, Hassan II University of Casablanca, B.P. 146 Mohammedia, Morocco. Electronic address: aziz.amine@fstm.ac.ma.

Förderung

  • Université Hassan II Casablanca

Zitieren

APA

Karrat, A., & Amine, A. (2024). Innovative approaches to suppress non-specific adsorption in molecularly imprinted polymers for sensing applications. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116053

Vancouver

Karrat A, Amine A. Innovative approaches to suppress non-specific adsorption in molecularly imprinted polymers for sensing applications. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116053

BibTeX
@article{Karrat2024,
  author = {Karrat, Abdelhafid and Amine, Aziz},
  title = {Innovative approaches to suppress non-specific adsorption in molecularly imprinted polymers for sensing applications},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116053}
}
Kostenlos starten →