Designing a label‐free electrochemical aptasensor based on polypyrrole‐ l ‐cysteine‐reduced graphene oxide nanocomposite for detection of 25‐hydroxyvitamin D 3
Biotechnology and Applied Biochemistry · 2023
DOI: 10.1002/bab.2490 ↗At a glance
Journal article in Biotechnology and Applied Biochemistry, 2023. Written by Maryam Heydari and 4 co-authors. Institution: Nanotechnology Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Major MEDLINE topics: Aptamers, Nucleotide, Biosensing Techniques, Nanocomposites, Graphite. Cited 5 times so far (Crossref); 39 references. Funded by: Ahvaz Jundishapur University of Medical Sciences, Vice Chancellor of Research of Mashhad University of Medical Sciences, Mashhad, Iran.
Abstract (original language)
Reliable and precise quantification of 25‐hydroxyvitamin D 3 in clinical samples is vital because vitamin D 3 deficiency lead to several disorders, such as mental illness, osteoporosis, and coronavirus disease. Herein, we report the fabrication of a novel electrochemical aptasensor using a nanocomposite, including reduced graphene oxide, pyrrole, and l ‐cysteine, for the sensitive detection of 25‐hydroxyvitamin D 3 . Subsequently, the aptamer of 25‐hydroxyvitamin D 3 was immobilized on the surface of the modified electrode. Differential pulse voltammetry signals were utilized for studying the binding and measurement of 25‐hydroxyvitamin D 3 based on the oxidation peak. Under the optimum conditions, the designed electrochemical aptasensor exhibited a linear detection range of 0.001–150 nM, with a limit of detection of 0.006 nM. Furthermore, the proposed aptasensor selectively detected 25‐hydroxyvitamin D 3 compared to other analogs. Moreover, this aptasensor was successfully applied for the detection of 25‐hydroxyvitamin D 3 in human serum samples, which were quantified by the enzyme‐linked immunosorbent assay method. The acceptable recoveries of 82.67%–111.07% demonstrated that this proposed electrochemical aptasensor can be a promising alternative for clinical methods of vitamin D determination.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Nanotechnology Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
- Medicinal Chemistry Departments, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
- Medical Genetics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
- Metabolic Syndrome Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
- Department of Medical Biotechnology and Nanotechnology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
- Department of Modern Sciences and Technologies, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
ORCID profiles: Aida Gholoobi, Majid Rezayi
Funding
- Ahvaz Jundishapur University of Medical Sciences
- Vice Chancellor of Research of Mashhad University of Medical Sciences, Mashhad, Iran
Cite
APA
Heydari, M., Rahbar, N., Gholoobi, A., Mohammadinejad, A., & Rezayi, M. (2023). Designing a label‐free electrochemical aptasensor based on polypyrrole‐ l ‐cysteine‐reduced graphene oxide nanocomposite for detection of 25‐hydroxyvitamin D 3. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.2490
Vancouver
Heydari M, Rahbar N, Gholoobi A, Mohammadinejad A, Rezayi M. Designing a label‐free electrochemical aptasensor based on polypyrrole‐ l ‐cysteine‐reduced graphene oxide nanocomposite for detection of 25‐hydroxyvitamin D 3. Biotechnology and Applied Biochemistry. 2023. doi:10.1002/bab.2490
BibTeX
@article{Heydari2023,
author = {Heydari, Maryam and Rahbar, Nadereh and Gholoobi, Aida and Mohammadinejad, Arash and Rezayi, Majid},
title = {Designing a label‐free electrochemical aptasensor based on polypyrrole‐ l ‐cysteine‐reduced graphene oxide nanocomposite for detection of 25‐hydroxyvitamin D 3},
journal = {Biotechnology and Applied Biochemistry},
year = {2023},
doi = {10.1002/bab.2490}
}
EUVIMED