EUVIMEDEUVIMED entdecken
Crossref

Ultrafast and ultrasensitive electrochemical aptasensor for multiplexed monitoring of hemorrhagic transformation biomarker in acute ischemic stroke

Yawen Pan, Bowen Chai, Zixin Wang, Yingnan Zhou, Junfen Fan, Xunming Ji, Jing Wu, Qingfeng Ma, Haiping Zhao

Biosensors and Bioelectronics · 2026-11 · 312 · 119060

DOI: 10.1016/j.bios.2026.119060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Yawen Pan und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Science, China University of Geosciences (Beijing), Beijing, 100083, China. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques, Matrix Metalloproteinase 9, Ischemic Stroke. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Beijing Nova Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hemorrhagic transformation (HT) remains a life-threatening complication after acute ischemic stroke (AIS), yet no active predictive tool is available for early risk assessment. Herein, we develop an integrated triplex electrochemical aptasensing platform for the parallel and simultaneous quantification of three HT-associated biomarkers-matrix metalloproteinase-9 (MMP-9), fibronectin (FN), and plasminogen activator inhibitor-1 (PAI-1). The system enables parallel detection by inserting three independent screen-printed carbon electrodes (SPCEs) into a multi-channel electrochemical workstation, each functionalized with a distinct aptamer, allowing simultaneous quantification of MMP-9, FN, and PAI-1 within 30 min. Each SPCE is modified with a conductive polypyrrole/poly(3,4-ethylenedioxythiophene):polystyrene sulfonate/polyvinyl alcohol hydrogel and gold nanoparticles, followed by immobilization of specific thiolated aptamers via Au-S bonds. Upon target binding, aptamer conformational changes induce a concentration-dependent decrease in differential pulse voltammetry current. The sensor achieves ultralow detection limits of 4.04 fg/mL, 0.30 fg/mL, and 2.79 fg/mL for MMP-9, FN, and PAI-1, respectively, with a total assay time of 30 min. Clinical validation using plasma from 12 AIS patients demonstrates excellent agreement with enzyme-linked immunosorbent assay (mean bias

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesMatrix Metalloproteinase 9Ischemic StrokeFibronectinsPlasminogen Activator Inhibitor 1HumansBiomarkersGoldElectrochemical TechniquesLimit of DetectionMetal NanoparticlesPolymersPyrroles

Stichwörter der Autor:innen

BiomarkersElectrochemical aptasensorHemorrhagic transformationHydrogel-derived nanostructuresSimultaneous detection

Substanzen

Aptamers, NucleotideBiomarkersMatrix Metalloproteinase 9GoldFibronectinsPlasminogen Activator Inhibitor 1PolymersPyrroles

Autor:innen und Institutionen

  • School of Science, China University of Geosciences (Beijing), Beijing, 100083, China.
  • Department of Neurology, Xuanwu Hospital of Capital Medical University, Beijing, 100053, China.
  • Neuro-Cardio-Vascular Diseases Research Lab, Xuanwu Hospital of Capital Medical University, Beijing, 100053, China.
  • Department of Neurology, Xuanwu Hospital of Capital Medical University, Beijing, 100053, China; Neuro-Cardio-Vascular Diseases Research Lab, Xuanwu Hospital of Capital Medical University, Beijing, 100053, China.
  • School of Science, China University of Geosciences (Beijing), Beijing, 100083, China. Electronic address: wujing@cugb.edu.cn.
  • Department of Neurology, Xuanwu Hospital of Capital Medical University, Beijing, 100053, China. Electronic address: m.qingfeng@163.com.

Förderung

  • Beijing Nova Program

Zitieren

APA

Pan, Y., Chai, B., Wang, Z., Zhou, Y., Fan, J., Ji, X., Wu, J., Ma, Q., & Zhao, H. (2026). Ultrafast and ultrasensitive electrochemical aptasensor for multiplexed monitoring of hemorrhagic transformation biomarker in acute ischemic stroke. Biosensors and Bioelectronics, 312, 119060. https://doi.org/10.1016/j.bios.2026.119060

Vancouver

Pan Y, Chai B, Wang Z, Zhou Y, Fan J, Ji X, et al. Ultrafast and ultrasensitive electrochemical aptasensor for multiplexed monitoring of hemorrhagic transformation biomarker in acute ischemic stroke. Biosensors and Bioelectronics. 2026;312:119060. doi:10.1016/j.bios.2026.119060

BibTeX
@article{Pan2026,
  author = {Pan, Yawen and Chai, Bowen and Wang, Zixin and Zhou, Yingnan and Fan, Junfen and Ji, Xunming and Wu, Jing and Ma, Qingfeng and Zhao, Haiping},
  title = {Ultrafast and ultrasensitive electrochemical aptasensor for multiplexed monitoring of hemorrhagic transformation biomarker in acute ischemic stroke},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {312},
  pages = {119060},
  doi = {10.1016/j.bios.2026.119060}
}
Kostenlos starten →