EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Exposition of Radiation‐Stabilized Polypropylene Copolymer to Repeated Injection Molding and γ ‐Radiation

Nele Espelage, Josephine Linette Liebal, Marius Behnecke, Karsten Kömpe, Markus Lothar Susoff, Peter Blömer, Martin Steinhart, Svea Petersen

Journal of Applied Polymer Science · 10.02.2026 · 143 (6)

DOI: 10.1002/app.70003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Polymer Science, online erschienen am 14.11.2025. Verfasst von Nele Espelage und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High‐quality requirements for plastic components in healthcare limit their recyclability. This study examined the stability of a representative polypropylene copolymer (PP‐C) containing Tinuvin 622 (T622) as a light stabilizer and calcium stearate (CaSt) as an acid scavenger during successive recycling steps involving γ ‐irradiation, mimicking medical sterilization. Chemical, thermal, rheological and mechanical properties of PP‐C were analyzed throughout various recycling stages. Differential scanning calorimetry and x‐ray scattering revealed little impact of γ ‐irradiation on crystallinity and polymorph formation. The influence of γ ‐irradiation on the chemical and mechanical properties of the PP‐C specimens was large compared to the processing‐related changes to the material properties. T622 content decreased by 22% after four cycles involving γ ‐irradiation, while the formation of volatile substances increased substantially. Zero‐shear viscosity dropped by 80%, indicating a corresponding decrease in molecular weight. Elongation at break increased with each cycle without γ ‐irradiation and decreased with γ ‐irradiation. Since elongation at break did not drop below critical levels, molecular weight likely remained above the threshold for maintaining the required mechanical properties. The decisive influence of γ ‐irradiation over processing effects suggests that although performance declines with γ ‐irradiation, PP‐C retains sufficient stability. These findings support the feasibility of recycling PP‐C for healthcare applications under the conditions considered.

Zitieren

APA

Espelage, N., Liebal, J. L., Behnecke, M., Kömpe, K., Susoff, M. L., Blömer, P., Steinhart, M., & Petersen, S. (2026). Exposition of Radiation‐Stabilized Polypropylene Copolymer to Repeated Injection Molding and γ ‐Radiation. Journal of Applied Polymer Science, 143(6). https://doi.org/10.1002/app.70003

Vancouver

Espelage N, Liebal JL, Behnecke M, Kömpe K, Susoff ML, Blömer P, et al. Exposition of Radiation‐Stabilized Polypropylene Copolymer to Repeated Injection Molding and γ ‐Radiation. Journal of Applied Polymer Science. 2026;143(6). doi:10.1002/app.70003

BibTeX
@article{Espelage2026,
  author = {Espelage, Nele and Liebal, Josephine Linette and Behnecke, Marius and Kömpe, Karsten and Susoff, Markus Lothar and Blömer, Peter and Steinhart, Martin and Petersen, Svea},
  title = {Exposition of Radiation‐Stabilized Polypropylene Copolymer to Repeated Injection Molding and γ ‐Radiation},
  journal = {Journal of Applied Polymer Science},
  year = {2026},
  volume = {143},
  number = {6},
  doi = {10.1002/app.70003}
}
Kostenlos starten →