EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Pressure‐Induced Drift Artifacts in Stretchable Liquid Metal ThinFilm Electrocardiogram Electrodes

Ding Li, Zi-Gan Xu iD, Zhi-Kang Chen, Shuo-Yan Xu, Jia-Yi Cui, Si-Yuan Wo, Zi-Xu Wang, Yi-Kun Liu, Jia-Ju Yin, Hou-Fang Liu iD, Xiao-Ming Wu, Lu-Qi Tao and 2 more

Advanced Science · 2026

DOI: 10.1002/advs.76002 ↗

At a glance

Journal article in Advanced Science, 2026. Written by Ding Li and 13 co-authors. Institution: School of Integrated Circuit, Tsinghua University, Beijing, China. Major MEDLINE topics: Artifacts, Electrocardiography. Cited 1 times so far (Crossref); 34 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Natural Science Foundation of China, Scientific and Technological Innovation Project of China Academy of Chinese Medical Sciences, Institute for Intelligent Healthcare at Tsinghua University.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Reliably monitoring epidermal electrophysiological signals with precision is essential for advanced healthcare systems and next‐generation human‐machine interfaces. Although stretchable thin‐film electrodes have shown promise for accurate electrocardiogram signal acquisition, the issue of pressure‐induced drift artifacts remains largely overlooked. We developed a stretchable LM thin‐film electrode integrated with an LM strain sensor to quantitatively investigate the drift artifact alongside skin deformation simultaneously and in situ. While most existing research focuses on strain‐induced drift, our findings reveal that the pressure‐induced drift artifact is more significant in stretchable LM electrodes. This work further emphasizes the limitations of the skin‐electrode impedance model in explaining the pressure‐induced drift, and confirms that its primary origin lies in skin potential change. Based on this, we validated an adaptive filtering method using the noise signal reconstructed from strain sensor data to calibrate pressure‐induced drifts. Compared to traditional static filtering methods, it demonstrates superior performance in suppressing irregular pressure‐induced drift artifacts

Subjects

MeSH terms (MEDLINE)

ArtifactsElectrocardiographyElectrodesHumansPressureEquipment Design

Author keywords

electrocardiogramliquid metalmotion artifactsstrain sensorsstretchablethin‐film electrodes

Authors and institutions

  • School of Integrated Circuit, Tsinghua University, Beijing, China.
  • Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing, China.

ORCID profiles: Zi-Gan Xu, Hou-Fang Liu

Funding

  • National Natural Science Foundation of China
  • Scientific and Technological Innovation Project of China Academy of Chinese Medical Sciences
  • Institute for Intelligent Healthcare at Tsinghua University

Cite

APA

Li, D., Xu, Z. G., Chen, Z. K., Xu, S. Y., Cui, J. Y., Wo, S. Y., Wang, Z. X., Liu, Y. K., Yin, J. J., Liu, H. F., Wu, X. M., Tao, L. Q., Yang, Y., & Ren, T. L. (2026). Pressure‐Induced Drift Artifacts in Stretchable Liquid Metal ThinFilm Electrocardiogram Electrodes. Advanced Science. https://doi.org/10.1002/advs.76002

Vancouver

Li D, Xu ZG, Chen ZK, Xu SY, Cui JY, Wo SY, et al. Pressure‐Induced Drift Artifacts in Stretchable Liquid Metal ThinFilm Electrocardiogram Electrodes. Advanced Science. 2026. doi:10.1002/advs.76002

BibTeX
@article{Li2026,
  author = {Li, Ding and Xu, Zi-Gan and Chen, Zhi-Kang and Xu, Shuo-Yan and Cui, Jia-Yi and Wo, Si-Yuan and Wang, Zi-Xu and Liu, Yi-Kun and Yin, Jia-Ju and Liu, Hou-Fang and Wu, Xiao-Ming and Tao, Lu-Qi and Yang, Yi and Ren, Tian-Ling},
  title = {Pressure‐Induced Drift Artifacts in Stretchable Liquid Metal ThinFilm Electrocardiogram Electrodes},
  journal = {Advanced Science},
  year = {2026},
  doi = {10.1002/advs.76002}
}
Start for free →