EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Label‐Free Metal‐Oxide Transistor Biosensors for Metabolite Detection in Human Saliva

Abhinav Sharma, Hendrik Faber, Wejdan S AlGhamdi, Dipti Naphade, Yen-Hung Lin, Martin Heeney, Thomas D Anthopoulos iD

Advanced Science · 2024

DOI: 10.1002/advs.202306038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, 2024. Verfasst von Abhinav Sharma und 6 weiteren Autor:innen. Beteiligte Einrichtung: King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal, 23955-6900, Saudi Arabia. Hauptthemen laut MEDLINE: Saliva, Biosensing Techniques, Uric Acid, Transistors, Electronic. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 85 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Abdullah University of Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Metabolites are essential molecules involved in various metabolic processes, and their deficiencies and excessive concentrations can trigger significant physiological consequences. The detection of multiple metabolites within a non‐invasively collected biofluid could facilitate early prognosis and diagnosis of severe diseases. Here, a metal oxide heterojunction transistor (HJ‐TFT) sensor is developed for the label‐free, rapid detection of uric acid (UA) and 25(OH)Vitamin‐D3 (Vit‐D3) in human saliva. The HJ‐TFTs utilize a solution‐processed In 2 O 3 /ZnO channel functionalized with uricase enzyme and Vit‐D3 antibody for the selective detection of UA and Vit‐D3, respectively. The ultra‐thin tri‐channel architecture facilitates strong coupling between the electrons transported along the buried In 2 O 3 /ZnO heterointerface and the electrostatic perturbations caused by the interactions between the surface‐immobilized bioreceptors and target analytes. The biosensors can detect a wide range of concentrations of UA (from 500 n m to 1000 µM) and Vit‐D3 (from 100 pM to 120 n m ) in human saliva within 60 s. Moreover, the biosensors exhibit good linearity with the physiological concentration of metabolites and limit of detections of ≈152 n m for UA and ≈7 pM for Vit‐D3 in real saliva. The specificity is demonstrated against various interfering species, including other metabolites and proteins found in saliva, further showcasing its capabilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaBiosensing TechniquesUric AcidTransistors, ElectronicHumansOxidesIndiumZinc OxideEquipment Design

Stichwörter der Autor:innen

human salivametabolite sensingmetal oxide transistornon‐invasive sensortransistor biosensor

Substanzen

Uric AcidOxidesindium oxideIndiumZinc Oxide

Autor:innen und Institutionen

  • King Abdullah University of Science and Technology (KAUST), KAUST Solar Center (KSC), Thuwal, 23955-6900, Saudi Arabia.
  • Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
  • Photon Science Institute, Henry Royce Institute, Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, M13 9PL, United Kingdom.

ORCID-Profile: Thomas D Anthopoulos

Förderung

  • King Abdullah University of Science and Technology

Zitieren

APA

Sharma, A., Faber, H., AlGhamdi, W. S., Naphade, D., Lin, Y. H., Heeney, M., & Anthopoulos, T. D. (2024). Label‐Free Metal‐Oxide Transistor Biosensors for Metabolite Detection in Human Saliva. Advanced Science. https://doi.org/10.1002/advs.202306038

Vancouver

Sharma A, Faber H, AlGhamdi WS, Naphade D, Lin YH, Heeney M, et al. Label‐Free Metal‐Oxide Transistor Biosensors for Metabolite Detection in Human Saliva. Advanced Science. 2024. doi:10.1002/advs.202306038

BibTeX
@article{Sharma2024,
  author = {Sharma, Abhinav and Faber, Hendrik and AlGhamdi, Wejdan S and Naphade, Dipti and Lin, Yen-Hung and Heeney, Martin and Anthopoulos, Thomas D},
  title = {Label‐Free Metal‐Oxide Transistor Biosensors for Metabolite Detection in Human Saliva},
  journal = {Advanced Science},
  year = {2024},
  doi = {10.1002/advs.202306038}
}
Kostenlos starten →